In spaces with combustion devices
Install the detector at 1 to 3 meters away from combustion devices, within the air flow
from the combustion device.
Install the detector way from of roof ridges, corners. arched ceilings or front roofs.
In the case of smaller spaces (<4m³), the detector should be installed outside these spaces.
Install the detector 61 centimeters from surrounding walls and ceilings.
It is recommended to install the device on the ceiling of a room with a combustion device.
90 cm
minimaal
61 cm
minimaal
> 61 cm
33
90 cm
minimaal
Not in this
Dode lucht
area
ruimte
1 - 3 m
Not in this
Niet in
area
deze ruimte
Near this
In de buurt
area
van deze
ruimte