1 . 3.- Technical specifications Power supply unit ref. 5029
Power
Input level:
supply
Output level:
(1)
If using 24V and/or 18V, you need to take the power consumed by these away from the 15V power.
2.- REFERENCE DESCRIPTION
Ref. 7310 .... SAT-RF
Ref. 5075 .... Hybrid amplifier
Ref. 5029 .... Power supply unit
Ref. 5301
230 ± 15 % V~
5V, 15V, 18V, 24V
(46 - 862 MHz)
(47 - 862 MHz)
(230 V ± 15 % - 50/60 Hz)
(24 V - 0,55 A)
(18 V - 0,8 A)
(1)
(15 V - 4,2 A)
(5 V - 6,6 A)
Ref. 5072
21
Maximum currents:
Ref. 7234 .... Universal programmer
Ref. 5071 .... Standard mounting rail (10 mod. + PSU)
Ref. 5239 .... Mounting rail (12 mod. + PSU)
Ref. 5073 .... Blank plate
Ref. 4061 .... 75 ohm terminal load F connector
Ref. 5072 .... Lockable cabinet
Ref. 5301 .... Rack frame 19"
Ref. 5253 .... Subrack interconnecting bus
Ref. 5255 .... Interconnection T03/T05
Ref. 5052 .... PAL headend control
Ref. 8250 .... Rack 19"
SAT-RF
24V
(0,55 A)
18V
(0,8 A)
(1)
15V
(4,2 A)
5V
(6,6 A)