GENERAL SETTINGS
UNIT OF TEMPERATURE MEASUREMENT
OPERATION
QUICK COOLING CYCLES
SOFT QUICK COOLING CYCLE WITH CORE TEMPERATURE PROBE: A suitable cycle for cooling foodstuffs
with a thickness less than 4 cm using a cabinet interior temperature of approximately 0°C. The cycle is controlled
by a core temperature probe.
HARD QUICK COOLING CYCLE WITH CORE TEMPERATURE PROBE: A suitable cycle for cooling foodstuffs
with a thickness of more than 4 cm using a cabinet interior temperature varying between -30°C and -5°C. The
cycle is controlled by a core temperature probe.
QUICK FREEZING CYCLE WITH CORE TEMPERATURE PROBE: A cycle suitable for freezing foodstuffs using
a cabinet interior temperature of approximately -30°C. The cycle is controlled by a core temperature probe.
TIME-CONTROLLED SOFT QUICK COOLING CYCLE: A suitable cycle for cooling foodstuffs with a thickness
of less than 4 cm using a cabinet interior temperature of approximately 0°C. The cycle is time-controlled.
TIME-CONTROLLED HARD QUICK COOLING CYCLE: A suitable cycle for cooling foodstuffs with a thickness
of more than 4 cm using a cabinet interior temperature ranging from -30°C to -5°C. The cycle is time-controlled.
TIME-CONTROLLED QUICK FREEZING CYCLE: A cycle suitable for freezing foodstuffs using a cabinet interior
temperature of approximately -30°C. The cycle is time-controlled.
NOTE: After the end of the quick cooling phase the appliance automatically starts the storing phase (+2°C for the
quick cooling cycle; -22°C for the quick freezomg cycle).
If a cycle by error has been started and you want to stop it, press the Standby button and a new program can be
selected.
Press the Defrost and Standby keys for 3 seconds with the control in Off mode to enter
the parameter programming mode.
The display shows "PASS".
Use the Up and Down keys to scroll through all the user parameters and display the
parameter "P0".
To confi rm your selection, press the quick freezing with core temperature probe key.
Use the Up and Down keys to select the new parameter value.
(0 Fahrenheit, 1 Celsius).
Press the quick freezing with core temperature probe key to confi rm your selection.
Press the Standby key to exit the selection program.
23