7 TROUBLE-SHOOTING
7.1 ALARMS MANAGEMENT (ADDRESSED TO QUALIFIED PERSONNEL)
The "OMEGA" electronic card is a powerful control logic unit which signals possible
machine troubles by means of alphanumeric messages visualized on the display; the
technician shall understand them to quickly find the reason of this trouble.
In order to visualize the alarm signal it is necessary connect to the OMEGA card the push
panel of model VIBE, code ...
MESSAGE
EME
The cover is open or the outlet door is not correct assembled
EMERGENCY
TER
MOTOR
THERMAL
CUTOUT ALARM
When the machine is started up, the microprocessor checks
EPO
STORED DATA
ALARM
EPI
MEMORY ALARM
LI
POWER SUPPLY
ALARM
OUT
USCITE MODULE
ALARM
TA
TA ALARM
UTA
TA MICRO-
PROCESSOR
ALARM
25 - ENGLISH
DESCRIPTION
An intermittent beep is released.
When a motor thermal cutout is triggered, it is followed by
the blinking of the led TER and by the release of an
intermittent beep.
the data stored in the EPROM memory: if this data are not
correct EPO will appear on the display, followed by the
release of an intermittent beep.
If, during normal functioning, the memory is not
acknowledged, EPI will appear on the display, followed by
the release of an intermittent beep.
If, during normal functioning, the voltage is too low, LI will
appear on the display, followed by the release of an
intermittent beep.
If, during normal functioning, the output control module is
faulty or if it is not acknowledged, OUT will appear on the
display, followed by the release of an intermittent beep.
If, during normal functioning, an anomaly of the current
transformer occurs, TA will appear on the display, followed
by the release of an intermittent beep.
If, during normal functioning, an anomaly of the
microprocessor controlling the consistency calibration
occurs, UTA will appear on the display, followed by the
release of an intermittent beep.
REMEDIES
Close the cover and /or
assemble correctly the
outlet door
After checking the
machine, press STOP to
restore correct
functioning.
Reset electronic card
Re-install the software
Replace electronic card
Reset electronic card
Re-install the software
Replace electronic card
Check mains voltage
and machine power
supply.
Verify FLAT
Reset electronic card
Replace modular
Replace electronic card
Verify wiring TA
Replace TA
Reset electronic card
Re-install software
Replace micro TA