5.
Operating the Revolving Console
The Lagos has a maximum rotational angle of 90 degrees;
you can adjust the rotational angle in 15-degree increments.
Unlock the rotary console by briefl y pressing the button A and
then turn the Lagos to the desired position. Shortly before the
fi nal position is reached, press the key A again and lock the
stove into place with a slight rotational movement.
A
fi g. 3
WARNING!
Never turn stove when lighting fi re!
In the whole rotational area range, the safe
distances (radiation area) apply to distances
to fl ammable materials.
2. Vorbereitung zur Montage
2.5 Drehwinkel am Aufstellort einstellen
fi g. 4
fi g. 5
6. Heat Retaining Block (optional)
Above the combustion chamber, there are solid storage ashlars
made from Magnetite. These store the heat of the fi re and ra-
diate it slowly once again, providing prolonged warmth. The
storage ashlars mean that only upward outfl ow is possible.
7 . Initial Operation
NOTE!
During shipment, condensation moisture can
accumulate in the stove's interior, which may
possibly lead to the appearance of
condensation or water on the stove or fl ue
pipes. Please dry off these damp areas imme
diately.
The surface of your stove was treated in a sandblasting ma-
chine before applying the colour coating. Despite careful and
thorough inspection, there may still be some residual material
in the stove body, which can fall out when your stove is being
installed.
NOTE!
To prevent any damage, please immediately
vacuum up these small steel pellets with a
vacuum cleaner.
The fi rst time a stove is operated, the heat development
causes the emission of volatile components from the coating,
sealing strips and lubricants, and smoke and odours can occur.
At a higher combustion temperature, this one-time process
can take between 4 to 5 hours.
To achieve this higher combustion temperature, please incre-
31