I n t e r n a t i o n a l T r a v e l / I n t r o d u c t i o n / I m p o r t a n t P a r t s
To reduce the risk of electrocution:
1. Do not use while bathing.
2. Do not place or store product where it can fall or be pulled into a tub or sink.
3. Do not place in or drop into water or other liquid.
4. Do not reach for a product that has fallen into water. Unplug immediately.
To reduce the risk of burns, electrocution, fire or injury to persons:
1. Close supervision is necessary when this product is used by, on, or near children or invalids.
2. Use this product only for its intended use as described in this guide.
3. Never operate this product if
a. It has a damaged power cord or plug.
b. It is not working properly.
c. It has been dropped or damaged.
d. It has been dropped into water.
Return the product to an authorized Laerdal Medical service center for examination and repair.
4. Keep the power cord away from heated surfaces.
5. Never use while drowsy or asleep.
NOTE– The 88 00 40 series is not factory equipped with an internal rechargeable battery; it may be purchased separately and installed by your Laerdal Medical provider.
88 00 20 and 88 00 30 series are factory equipped with an internal rechargeable battery and all information regarding battery operation in this guide is applicable.
This suction unit is a vacuum suction device designed for the collection of nonflammable fluid materials in medical applications only.
Improper use during medical applications can cause injury or death. For all medical applications:
1. All suctioning should be done in strict accordance with appropriate procedures that have been established by a licensed medical authority.
2. Some attachments or accessories may not fit the tubing supplied. All attachments or accessories should be checked prior to use to assure proper fit.
INTERNATIONAL TRAVEL
The suction unit is equipped with a switch mode power supply allowing operation on any AC voltage (100-240 VAC, 50/60 Hz). However the correct
power cord must be used to connect to adaptable wall power.
NOTE– Check power cord for adaptability before using.
INTRODUCTION
Your suction unit is a compact medical suctioning device which has been designed for reliable, portable operation. Because of the small size, light
weight and multi-source powering, this suction unit is ideal for providing emergency suction in the field, home, transport, and hospital treatment
environment. Two collection bottle options give the choice between the economical 800 ml disposable canister or the 1,200 ml reusable canister.
Following the recommended operating and maintenance procedures outlined in this instruction guide will maximize the life of this product.
IMPORTANT PARTS OF YOUR SUCTION UNIT (refer to diagram)
Description
1
Bacteria filter (non-sterile)
2
4" Connection tubing
3
Vacuum gauge
4
Tubing connector
5
Vacuum regulator knob
6
DC power input (on side)
7
Power switch
8
6' patient tubing
9
800 cc disposable canister w/lid
(float shut off incorporated into lid)
10
90° connection elbow
Switch mode adapter (not shown)
Internal rechargeable battery (not shown) 88 00 20 & 88 00 30 series
Carrying case (not shown)
DC Cable (not shown)
Mains Cable (not shown)
NOTE– This unit complies with electromagnetic compatibility standards as defined in the included
Declaration of Conformity.
DANGER
WARNING
DANGER
Factory equipped on models:
All models
All models --
8mmID FDA approved Silicone tubing.
Use only specified connection tubing
All models
for replacement.
All models
All models
All models
All models
All models --
.25"ID x 6' FDA approved PVC tubing
with connecting couplers. Use only
All models
specified patient tubing for replacement.
All models
All models
All models
All models
All models
E n g l i s h
10
1
2
9
8
3
3
4
5
6
7
100-405-00