Machine Function Messages; Display Indication - Nuova Simonelli MICROBAR II Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

EN
9.

MACHINE FUNCTION MESSAGES

DISPLAY INDICATION

GROUNDS DRAWER FULL
Machine Ready
Drawer Full
GROUNDS DRAWER
OUT OF PLACE
Machine Ready
Drawer Out
MACHINE FRONT PANEL
POSITION
Macchine
Front Panel Open
WASHING CYCLE IS
REQUIRED
Clean Warning
CAUSE
Grounds drawer
full. The number
of coffee grounds
in the drawer
has reached the
number set dur-
ing programming
stage.
Grounds drawer
out of place.
Front
panel
open.
OFF
The set number
of cycles pro-
grammed before
washing,
been exceeded.
EFFECT
Keys delivering
coffee
based
drinks
are
blocked.
Keys delivering
coffee
based
drinks
are
blocked.
The
machine
functions
are
blocked.
The message
will appear on
the display but
has
the
machine
will continue to
deliver drinks.
SOLUTION
Pull out the grounds drawer and
empty it into a garbage bag.
Put the drawer back into place,
when the display reads:
Machine Ready
Drawer Out
Insert the grounds drawer into its
special slot.
Should this alarm turn on during
the delivery of a coffee based
drink:
Up until brewing, the alarm is
displayed but the drink will be
delivered.
After brewing, the cycle in
progress will be suspended.
The coffee cycle will recom-
mence only when the draw-
er has been put back in its
place.
Should this alarm turn on during
the group movement phase:
the movement will be inter-
rupted.
When the drawer is back in its
place, the reset group will be
repeated.
Close the front panel.
Do a washing cycle (see
paragraph
"WASHING
DELIVERY UNIT AND MILK
FOAMER").