13. CLEANING ALARM
Press the ENTER key to access the setting.
Cleaning Warning
It allows you to program the number of cycles
after which the group clean warning will be
displayed.
KEY FUNCTIONS
:
Increase/decrease of the cycle number
before message visualization.
ENTER: /
RESET: Return to the previous menu with the con-
firmation of the value set.
14. RINSING UNIT
Press the ENTER key to access the setting.
Rinse Group
A rinsing cycle of the delivery unit is pro-
grammed.
When enabled (ON), the machine carries out a
rinsing cycle of the unit after 20 minutes from
the last activity (if the machine does not per-
form any activity before 20 minutes).
KEY FUNCTIONS
:
Enabling/disabling (ON/OFF) the unit rinsing.
ENTER: Confirmation of the setting and return to
the previous menu.
RESET: Return to the previous menu.
15. GROUP 1 ADJUSTMENT
Press the ENTER key to access the setting.
Group Setting 1
0000
The number of ENCODER pulses is pro-
grammed so that the infusion chamber reaches
the stand-by position.
KEY FUNCTIONS
:
Increase/decrease of the pulse number of
the ENCODER.
ENTER: /
RESET: Return to the previous menu with the con-
firmation of the value set.
IMPORTANT:
It is recommended to modify the setting only in case
the original reduced gear is replaced with a different
type.
16. GROUP 2 ADJUSTMENT
Press the ENTER key to access the setting.
Group Setting 2
0000
The number of ENCODER pulses is pro-
grammed so that the infusion chamber reaches
the upper position (chamber closed).
KEY FUNCTIONS
:
Increase/decrease of the pulse number of
the ENCODER.
ENTER: /
RESET: Return to the previous menu with the con-
firmation of the value set.
IMPORTANT:
It is recommended to modify the setting only in case
the original reduced gear is replaced with a different
type.
17. COFFEE TEMPERAT.
Press the ENTER key to access the setting.
Coffee Temperat.
0098 C
The temperature of the coffee heater is pro-
grammed.
KEY FUNCTIONS
:
Increase / decrease of the coffee boiler
temperature. The max. temperature that
can be set is 105°C (221°F).
ENTER: /
RESET: Return to the previous menu with the con-
firmation of the value set.