Standard press seal HSD SSG
Contents
1
Publishing notes ...............................................13
2
Explanation of symbols ....................................13
3
Required tool and auxiliaries ...........................13
4
Description ........................................................13
5
Preparing for assembly ....................................13
5.1
Mount the standard press seal from
the outside of building ....................................13
5.2
Retrofi tted splitting of standard press seal
(HSD 150/200/250 und 300-SSG) on already
laid pipes ...........................................................13
5.3
Mount the standard press seal from
the inside of building ......................................14
6
Attaching the FHRK seal ...................................14
1
Publishing notes
Copyright © 2019 by
Hauff-Technik GmbH & Co. KG
Dept.: Technical Editing
Robert-Bosch-Straße 9
89568 Hermaringen, GERMANY
Tel.
+49 7322 1333-0
Fax
+49 7322 1333-999
E-mail
offi ce@hauff-technik.de
Internet
www.hauff-technik.de
Reproduction of these assembly instruction – even in
extracts – in the form of reprint, photocopy, on electro-
nic data media or using any other method requires our
written consent.
All rights reserved.
Subject to technical alterations at any time and without
prior announcement.
These assembly instruction is component of the product.
Printed in the Federal Republic of Germany.
2
Explanation of symbols
1
Work stages
►
Effect/result of a work step
1
Reference numerals in drawings
3
Required tool and auxiliaries
For correctly assembly of the the standard press seal
HSD100 SSG or HSD150 SSG, HSD200 SSG, HSD250 SSG
and HSD300 SSG you will need the following tools and
aids in addition to the usual tools:
Assembly set for HSI150 DG/HRK SSG (Article no.:
2102200600), consisting of:
1 Torque spanner 4-20 Nm, 1/4 inch
1 Extension 100 mm, 1/4 inch
2 Extensions 150 mm, 1/4 inch
1 Adapter for cordless screwdriver, square, 1/4 inch
1 M6 socket, wrench size 5, 1/4 inch with spherical
Auxiliaries:
4
Description: HSD200 SSG 1x110/125/135/160 b40 (see
fi g.: 1).
Legend for fi g.: 1
1
2
3
4
5
6
5
1
Legend for fi g.: 2
1
2
5.1 Mount the standard press seal from
2a
2b
3a
Art. Nr.: 5090032038
Rev.: 06/2019-11-27
head
1 M8 socket, wrench size 6, 1/4 inch with spherical
head
1 Lubricant GM (Art.Nr.: 080420000)
1 Cutter knife
1 Cleaning cloth
Description
Rear press segments
Allen screw
Front press segments
Blind plug
Elastomer segment/Rubber press ring
(Grade: EPDM or NBR)
Built-in inspection opening
Preparing for assembly
Clean the core drilling/liner and media line.
Level out any chips and/or voids which may be
present.
Check the diameter tolerance of the core drilling/
liner (D -1+2 mm) and media line (d) (see table 1),
as well as outer or drilling dimension of the press
seal (see fi g.: 2).
The wall sleeve must be dimensionally accurate,
smooth and inherently stable.
Diameter (D) of the core drilling/wall sleeve
Diameter (d) of the medium pipe
the outside of building
Remove the blind system cover from the standard
press seal HSD150 SSG 1x75/90/110 b40,
HSD150 SSG 1x70-112 b40 and HSD200 SSG
1x110/125/135/160 b40 und HSD200 SSG
1x110-162 b40 (see fi g.: 3a).
Fold out and pull out the blind plug on the
HSD100 SSG 1x18-65 b40 and HSD100 SSG
1x25/32/40/50/63 b40 (see fi g.: 3b).
To open the standard press seal, loosen and remove
a screw at the partition cut (see fi g.: 4a).
EN