3.4 One mains connection cable
3.5 One compact protective pouch,
3.6 Six 1.5-V-batteries/ type AA (IEC LR6) fitted in the unit as original equipment,
3.7 One operating instructions manual
Parts subject to wear:
-
The BENNING ST 720 is provided with two fuses for overload protection:
two fuses with a nominal current of 16 A, 250 V, F, breaking capacity ≥ 500 A, D = 5 mm, L =
20 mm (P.no. 10019440)
-
The BENNING ST 720 is supplied by six 1.5 V batteries/ type AA (IEC LR6).
Note on optional accessories:
-
Test badges "next test", 300 pieces (756212)
-
Measuring adapter for three-phase loads (passive, without mains voltage-dependent switch-
ing devices)
for R
, R
(insulating resistance) and I
PE
ISO
-
16 A CEE coupling - shock-proof plug (044122)
-
32 A CEE coupling - shock-proof plug (044123)
-
Measuring adapter for three-phase loads (active, with mains voltage-dependent switching
devices)
for R
and I
PE
PE
-
16 A CEE adapter, three-phase, active (044140)
-
32 A CEE adapter, three-phase, active (044141)
As an alternative:
-
BENNING CM 9 leakage current clamp for measuring the differential current, protective
conductor current and load current of single-phase and three-phase loads (044065)
-
measuring adapter for BENNING CM 9 leakage current clamp, conductors led through indi-
vidually, with double insulation:
-
16 A shock-proof coupling - 16 A shock-proof plug (044131)
-
16 A CEE coupling - CEE plug (044127)
-
32 A CEE coupling - CEE plug (044128)
-
Test certificate forms for "Testing of electrical devices" are available for download free of
charge at www.benning.de
4.
Unit description
See figure 1:
See figure 2:
The display and operator control elements specified in Fig. 1 and 2 are designated as follows:
1 test socket, for connecting the device to be tested,
-key, testing of devices of protection class I (devices with protective conductor and ac-
2
cessible conductive parts which are connected to the protective conductor),
-key, testing of devices of protection class II (shock-proof devices without protective con-
3
ductor and with accessible conductive parts) and testing of devices of protection class III
(safety extra-low voltage),
-key, testing the protective conductor current (differential measurement) or contact current
4
(direct measurement) under operating conditions (test sample is supplied with mains voltage)
-key, reducing the testing voltage to 250 V
5
resistance
-key, testing of 30 mA RCDs
6
-key, testing of three-phase devices under operating conditions
7
8 Digital display, indicates the test progress and individual measuring results,
9 4 mm test socket, for connecting the test cable with alligator clip
J IEC connector, for connecting the IEC power cord
K Mains connection socket, for connecting the mains voltage (230 V, 50 Hz), for voltage
measurement at external shock-proof socket or for connecting the measuring signal cable
of the measuring adapter (16 A CEE adapter, three-phase, active/ 32 A CEE adapter, three-
phase, active)
5.
General information
The BENNING ST 720 is intended for electrical safety tests according to DIN VDE 0701-0702,
BGV A3 and ÖVE/ ÖNORM E8701.
Automatically, the BENNING ST 720 verifies the type of the connected test object and informs
the user in case of incorrect selection of the testing procedure [ 2 ... 3 ]: preset limiting values and
measuring results with "pass/ fail" information make it easier to evaluate the test.
-
At full battery capacity, the BENNING ST 720 allows to carry out approx. 2,500 device tests.
6.
Environment conditions:
-
The BENNING ST 720 is intended for making measurements in dry environment.
-
Maximum barometric elevation for making measurements: 2000 m,
-
Over voltage category/ Siting category: IEC 61010-1 → 300 V category II,
-
Contamination class: 2,
-
Protection Class: IP 40 (DIN VDE 0470-1 IEC/ EN 60529)
08/ 2010
measurements (direct measurement) under operating conditions:
Appliance front face
Top side of the device
BENNING ST 720
(alternative leakage current) measurements:
EA
or 500 V
DC
DC
for measuring the insulating
19