Operating instructions SATAjet 5000 B RP/HVLP
EN
Check sealing surfaces inside the spray gun [8-2] after disassembly,
clean them, if required. Should the sealing surfaces be damaged,
please contact your SATA dealer. Align new air distribution ring with the
help of the marking [8-3], (pin must be located in the drilling) and press
in with even force. Adjust material flow according to chapter 7.2 after
installation.
9.3. Replacing the paint needle sealing
[9-2] and [9-3]
When paint material leaks from the self-tensioning paint needle packing, it
needs to be replaced. Remove trigger according to [9.2]. After disassem-
bly, check if paint needle is damaged or replace the nozzle set, if re-
quired. Make sure that the trigger sleeve [9-2] is in correct position when
the trigger is reassembled. Adjust the material flow according to chapter
7.2 after installation.
9.4. Replacing the air piston, air piston spring and
air micrometer
• Disconnect the spray gun from the compressed air circuit!
This must be exchanged if air is leaking from the air nozzle or the air
micrometer while the trigger is not pulled. After disassembly, grease air
micrometer shell with SATA gun lubricant (item no. 48173), insert with
air piston and tighten locking screw using original SATA combination tool
with max. 1 Nm. [10-1]. After installation, set material throughput accord-
ing to chapter 7.2.
• Check if the locking screw has been firmly tightened! The air microm-
eter could shoot out from the spray gun uncontrolled!
108
Notice!
Steps: [10-1], [10-2] and [10-3]
Warning!
Warning!
Steps: [9-1],