8.
Settings
(press push-button 1 for a moment / LED signal lamp must be bright)
8.1. Operating modes
The TA 250/TA 450 can be operated in three different operating modes:
Automatic
Semi-automatic
Manual
Press and hold the SET button for 3 seconds to choose
one of the operating modes.
The operating mode which is set starts flashing.
Afterwards press one operating mode button of your
choice.
When you release the operating mode button you choose,
the LED will stop blinking after about 3 seconds and the
mode you set will be stored.
8.2. Tensioning force / welding time
Press and hold the adjust button for 3 seconds to adjust
the tensioning force or welding time until the number above
the adjust button flashes.
Now you can adjust the desired tensioning force / welding
time by pushing the adjust button repeatedly until the
desired value is displayed.
1 = low tensioning force / welding time
9 = high tensioning force / welding time
When you release the adjust button the set value will stop
blinking after about three seconds and the value you set will be
stored.
TA 250 / TA 450
(0001)
The setting only works when being enabled!
H TA 250 / 450 EU 09/15
Welding time
Tensioning
force
49 / 112