Operation; Extension Cord; Settings - Festool TS 75 EQ Notice D'utilisation D'origine

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

7

Operation

WARNING
Unauthorised voltage or frequency.
Risk of accidents
► The mains voltage and the frequency of the
power source must correspond to the
specifications on the name plate.
► In North America, only Festool machines
with the voltage specifications 120 V/60 Hz
may be used.
CAUTION
Heating of the Plug it connection if bayonet
fitting is not completely locked
Risk of burns
► Before switching on the power tool, make
sure that the bayonet fitting at the mains
cable is closed fully and locked.
Always switch off the machine before
connecting and disconnecting the mains
power cable.
Connecting and disconnecting the mains power
cable see Fig. [2].
Slide the safety lock [1.7] upwards and
press the on/off switch [1.8] (press =
ON / release = OFF).
Pressing the safety lock unlocks the plunging
mechanism. The saw unit can then be moved
downwards. This causes the saw blade to
emerge from the protective cover.
When the machine is lifted, the saw unit
springs back into its initial position.
7.1

Extension Cord

If an extension cord is required, it must have
sufficient cross-section to prevent an excessive
drop in voltage or overheating. An excessive
drop in voltage reduces the output and can lead
to failure of the motor. The table below shows
you the correct cord diameter as a function of
the cord length for this tool.
Cord Size in A.W.G
Tool`s Ampere Rating
3-6
6-8
8-10
10-12
12-16
Wire Sizes in mm
Tool`s Ampere Rat­
ing
3-6
6-8
8-10
10-12
12-16
Use only NRTL listed extension cords.
Never use two extension cords together. In­
stead, use one long one.
The lower the AWG number, the stronger
the cord.
8

Settings

Risk of injury, electric shock
► Always pull the mains plug out of the sock­
2
et before performing any type of work on
the machine!
8.1
Electronics
The machine features full-wave phase control
electronics with the following features:
Smooth start-up
The electronically controlled smooth start-up
function ensures that the power tool starts up
smoothly.
Constant speed
The motor speed is electronically kept con­
stant. This ensures a uniform cutting speed
even when under load.
Cord Length in Feet
25
50
100
18
16
16
18
16
14
18
16
14
16
16
14
14
12
-
2
Cord Length in Meters
15
30
60
0.75 0.75 1.5 2.5
0.75 1.0
2.5 4.0
0.75 1.0
2.5 4.0
1.0
2.5
4.0 -
-
-
-
WARNING
English
150
14
12
12
12
-
120
-
9

Publicité