Technical function data
The coils for type AC10 are available in 2 versions:
1.) Version for use with supply module 300 Ω (300 Ω barrier)
2.) Version for use with other approved supply modules (e.g. 8x remote I/O
from the manufacturer STAHL).
Version
Version for
use with 300 Ω
supply module
High-resistance
version
The maximum voltage and current values are predetermined by the
permissible electrical equipment.
Permissible ambient temperature range
Mounting/Temperature class
Individual mounting/T6
Block mounting/T6
Individual mounting/T5
Block mounting/T5
Type of protection: At least IP 20 according to EN 60529
8 - 01 ATEX 2101
Resistance
Minimum terminal
R20 [Ω]
voltage [V]
310
9
481
11,1
AC10-5-
-40 °C to +60 °C
-40°C to +60 °C
-40 °C to +75 °C
-40 °C to +75 °C
(DIN VDE 0470 part 1)
Minimum
Discrimination
current [mA]
number
29
10
23
11
AC 10-6-
-40 °C to +60 °C
not possible
-40 °C to +75 °C
not possible