9 Solving malfunctions and problems

Warning:
- When working on the equipment, the equipment must be voltage-free.
Table 1, Problems
Signal
Problem
LED on anti-
No high voltage at the
static bar does
emitters
not light up
LED on anti-
No high voltage at the
static bar
emitters
flashes green
LED on anti-
Anti-static bar
static bar lights
overloaded
up red
LED on anti-
No / poor ionization,
static bar lights
but high voltage at the
up green
emitters
LED on anti-
High voltage at the
static bar
emitters, but no HV
flashes red
OK signal
No high voltage at the
emitters
Vicinion_UM_9752152141_NL_D_GB_F_V1_3
Cause
No power supply
Wiring error
Connector wrongly
connected
No Remote on / off signal
Wiring error
Anti-static bar
contaminated
Anti-static bar mounted too
close to conductive
machine parts
Anti-static bar
contaminated
Emitters are damaged
Anti-static bar incorrectly
positioned
Emitters are covered
HV OK overloaded
Wiring fault
Supply voltage too low
Anti-static bar overheated
Solution
Switch on supply
voltage
See fault finding and
remedying, 5.4.3
Correctly align
connectors, see 5.4.1
Remote on / off
connect / activate
See fault finding and
remedying, 5.4.3
Clean anti-static bar
Reposition the anti-
static bar
Clean anti-static bar
Replace the anti-static
bar
Reposition the Anti-
static bar, see 5.2
Remove cover
Load HV OK
differently
See fault finding and
remedying, 5.4.3
Provide 24V DC at the
input of the anti-static
bar
Check if the ambient
temperature is below
55°C
40
GB
BE