Programmable Parameters - Beretta EXCLUSIVE BOILER GREEN 30 B.S.I. Manuel D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 21
EXCLUSI
EXCLUSI
EXCLUSI
EXCLUSIVE BOILER GREEN 30 B
EXCLUSI
VE BOILER GREEN 30 B.S .S .S .S .S.I .I .I .I .I. . . . .
VE BOILER GREEN 30 B
VE BOILER GREEN 30 B
VE BOILER GREEN 30 B

Programmable parameters

DESCRIPTION PARAMETERS
PAR.
1
GAS TYPE
2
BOILER POWER
3
INSULATION LEVEL OF BUILDING
10
DHW MODE
11
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
12
WATER TANK MAXIMUM SET-POINT
13
DELIVERY TERMPERATURE EXT. WATER TANK
14
DELTA EXTERNAL WATER TANK (ON)
20
HEATING MODE
21
HEATING CIRCUIT MAXIMUM SET-POINT
22
MINIMUM HEATING SET POINT
23
MAXIMUM HEATING VENTILATOR SPEED
24
MINIMUM HEATING VENTILATOR SPEED
25
DIFFERENTIAL HEATING POSITIVE
26
DIFFERENTIAL HEATING NEGATIVE
28
MAX HEATING POWER REDUCTION TIMER
29
FORCED HEATING SHUT DOWN TIMER
30
HEATING TIMER RESET FUNCTION
31
MAXIMUM HEATING SET POINT 2CH (II circuit)
32
MINIMUM HEATING SET POINT 2CH (II circuit)
40
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
41
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
42
S.A.R.A. FUNCTION
43
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
44
THERMOREGULATION FUNCTION
45
INCLINATION THERMOREGULATION CURVE (OTC)
46
THERMOREGULATION FUNCTION 2CH
47
INCLINATION THERMOREGULATION CURVE (OTC) 2CH
48
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
50
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
51
HEAT REQUEST TYPE CH1 (I circuit)
52
HEAT REQUEST TYPE CH2 (II circuit)
61
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
62
HEATING ANTIFREEZE FUNC. DELIVERY TEMP. (ON)
63
WATER TANK ANTIFREEZE FUNC. DELIV. TEMP. (ON)
65
EXTERNAL SENSOR REACTIVITY
85
SEMI-AUTOMATIC FILLING
86
AUTOMATIC FILLING PRESSURE (ON)
92
ENABLE POST-CIRCULATION FROM DHW TO HEATING
93
DURATION OF POST-CIRCULATION FROM DHW TO HEATING
94
PUMP IN CONTINUAL MODE CH1 (CIRCUIT 1)
95
PUMP IN CONTINUAL MODE CH2 (CIRCUIT 2)
*
Power not available at the moment
**
The value is expressed on the display in revs/min/100 (example 3.600 = 36)
1 6
1 6
1 6
1 6
1 6
UNIT OF
MIN
MEASURE
1 Methane
2 LPG
3 Methane France
10*-16-20*-26-30-34-50*-70*
min
5
0 (OFF)
1 (Instantaneous)
2 (Mini-tank)
3 (External water-tank with thermostat)
4 (External water-tank with sensor)
5 (Integrated water tank)
° C
40
° C
50
° C
0
0 (OFF)
1 (ON)
2 (not used)
3 (CONNECT AP)
4 (not used)
5 (not used)
6 (CONNECT AT/BT)
° C
40
° C
20
revs/min
36 (3.600**)
revs/min
G20
G31
30kW
14
14
° C
2
° C
2
min
0
min
0
-
0 (NO)
° C
40
° C
20
0 (OFF)
1 (AUTO)
0 (OFF)
1 (AUTO)
-
2,5
0 (OFF)
1 (AUTO)
-
2,5
-
0
-
0
°C
0
°C
0
0 (very fast)
0 (disabled)
1 (enabled)
bar
0.4
0
1
0
0
MAX
DEFAULT
(setted in
factory)
1
30
20
5
5
60
80
60
85
80
10
5
1
80
80
39
20
MAX
G20
G31
30kW
56
56
36 (3.600**)
MIN
10
6
10
6
20
15
20
5
1 (YES)
0
80
80
39
20
1
1
1
1
1
40
20
1
40
20
0
1
1
0
1
0
4
10
6
10
6
255 (very slow)
255
1
1.0
0.6
1
0
255
5
1
0
1
0
PARAMETERS
(setted by techn.
assist. centre)