Nemox GELATO NXT1 Mode D'emploi page 7

Masquer les pouces Voir aussi pour GELATO NXT1:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 9
Function
Operation
Pause function
1 TAP L.1
activation
Pause function
1 TAP L.1
deactivation
Manual activation of
TAP L.3
the storage function
1 x 3"
Selection of the
TAP L.3
storage cycle
Return to the
TAP L.3
production cycle from
1 x 3"
the storage phase
Turning off the
TAP L.1
machine
1 x 2"
ENGLISH
Description
Press the START L.1 key
It can be activated during the ice cream
formation or storage phase. Always use
when the cover is lifted for any reason. The
function is signalled by a beep every 10
seconds.
WARNING: the Pause lasts up to 10 minutes
after which the machine turns off
automatically. 5 beeps signal the turning
off.
Press the START L.1 key to exit the pause
function and return to the production or
storage phase.
Press the L.3 key for 3 seconds.
Activation of the storage phase. Selectable
at any time during the ice cream production
phase or during the pause.
WARNING: Storage lasts up to 8 hours. After
this time, the machine will turn off
automatically. 5 beeps signal the turning
off.
Press the L.3. key
If you want to manually select the density
during the storage phase, repeatedly press
the L.3 key to select a different density to
the default.
The larger LEDs indicate a higher density.
Smaller LEDs indicate a lower density.
Press the L.3 key for 3 seconds.
Activation of the production cycle.
Selectable at any time during the ice cream
storage phase.
Press the L.1 key for 2 seconds.
Stop all functions.
PANEL AND FUNCTIONS OF THE NXT1 L'AUTOMATICA
Led and sound
Switching from the production to the pause phase
- Led L.1 turned on
- TIME LINE Led L.2 flashing
- Pause start: audible signal (1 beep)
- Audible signal every 10 seconds (1 beep)
Switching from the storage to the pause phase
- Led L.1 turned on
- Led flashing on the DENSITY CONTROL bar
- Pause start: audible signal (1 beep)
- Audible signal every 10 seconds (1 beep)
Reaching the time limit:
- Led L.1 subtle lighting.
- Machine turned off: audible signal (5 beeps)
Exit pause phase
- Led L.1 turned on
- Led goes from flashing to steady.
- Blade re-start: audible signal (2 beeps)
Manual activation of the storage
- Led L.1 turned on
- Led L.2 TIME LINE all turned on
- Led L.3 storage key turned on
- Led L.4 DENSITY CONTROL turned on
- Storage start: audible signal (3 beeps)
Reaching the time limit:
- Machine turned off: audible signal (5 beeps)
Selecting the storage density
- Led L.1 turned on
- Led L.4 DENSITY CONTROL lights up corresponding to
the selection made.
- Led. TIME LINE L.2 all turned on
Return to production stage
- Led L.1 turned on
- TIME LINE Led L.2 light up gradually.
- Led L.3 Storage key turned off.
- DENSITY CONTROL Led L.4 turned off
- Blade movement : audible signal (2 beeps)
Turning off the machine
- Led L.1 subtle lighting.
- Machine turned off: audible signal (5 beeps)
PAG. 07

Publicité

Table des Matières
loading

Table des Matières