Storage
Temperature Coefficient: ±0,1% per °C
Power Supply:
Current consumption:
Battery life:
Not less than 1800, 5 second operations on 2Ω range.
Battery Condition Test:
battery voltage on a simulated load, when the 'Test' push button is
pressed. The instrument pointer should deflect clockwise to within the
'Battery Check' arc on the scale. Remove the battery if the instrument is
not to be used for an extended period of time.
Battery Replacement:
For safety reasons, the battery compartment must not be opened if the
test leads are connected. To remove the battery cover, release the screw
in the centre of the cover and lever the cover upwards.
Replaceable Fuse:
To check this fuse, open circuit the test leads, switch to the 200
and press the 'Test' push button. A reading of <200Ω indicates a ruptured
fuse. Located in the battery compartment, this fuse can be replaced by the
user. The replacement fuse must be of the correct type and rating.To
replace the fuse, disconnect the test leads, remove the battery cover by
releasing the screw in the centre of the cover and levering the cover
upwards. A spare fuse is clipped onto the battery cover.
Non Replaceable Fuse:
overall safety protection, this fuse is not replaceable by the user. No
response from the instrument to an insulation test, with the leads shorted
together is likely to mean that this fuse has ruptured. The instrument must
be returned to the manufacturer, or an approved agent for repair.
Safety:
Meets the requirements for double insulation to IEC1010-1
(1995) EN61010-1 (1995) to installation Category III***, 300 V
phase to earth (ground) and 500 V phase to phase, without
the need for separately fused test leads. If required, fused test
leads are available as an optional accessory. Indicates circuit
discharge after insulation test, 600 V Category II **.
*** Relates to transient overvoltage likely to be found in fixed
installation wiring.
** Relates to transient overvoltage likely to
be found in portable equipment and appliances.
E.M.C.
In accordance with IEC61326 including amendment No.1
Standards: BS 7430 (1992)
Weight:
485g
Dimensions: 175 mm x 95 mm x 57 mm.
Cleaning: Wipe disconnected instrument with a clean cloth dampened
with soapy water or Isopropyl Alcohol (IPA).
-20°C to + 70°C
Single 9V Alkaline battery I.E.C. 6 LR61 type
110 mA max on Insulation
40mA max on Resistance
220 mA max on 2 Ω range
The battery condition test position checks the
500 mA, 250V. H.B.C. type (F) (20mm. x 5mm)
2A - 500 V H.B.C. type (F) 50 kA. Fitted for
-
VDE 0413 (1982)
range