GF JRGURED UP 3/4 Notice D'utilisation Et D'entretien page 57

Masquer les pouces Voir aussi pour JRGURED UP 3/4:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Operating and maintenance instructions
Please read carefully the operating and
maintenance instructions.
The used symbols mean:
Danger
This symbol indicate a high risk of
injure for persons. It must be strictly
observed.
Warning
This symbol point out an information,
ignoring of it can cause extensive mate-
rial damage. The security information
has to be observed.
Note
This symbol point out an information,
which indicate important details con-
cerning the use of the valve. Ignoring
of it can result in trouble.
General information
The pressure reducer JRGURED UP is a compact
concealed valve for drinking water installations,
consisting of maintenance shut-off valve, coarse
filter and pressure reducer.
The built-in shut-off function is used
when maintaining the pressure reducer
and the downstream pipe installation.
Function
Water pressure in the installation system is to be
adjusted at an appropriate level.
The pressure-reducing valve JRGURED UP
decreases the inlet pressure to a lower,
constant outlet pressure.
The coarse filter integrated in the JRGURED UP
cartridge traps particulate matter greater than
1,000 µm. In case of significant pressure drop
when tapping water, clean or replace the coarse
filter (see Section 7).
E
57

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

1380.320

Table des Matières