All electrical installations must comply with local standards. All standards issued by national electrical authorities
must be complied with.
-
When circuit breakers are used, they must be suitable for a minimum of 30 mA.
-
Avoid obstruction of air intakes or outlets with objects (fabric, walls, etc).
-
Keep hot air off of the induction appliance (for example when several appliances are next to one another, or behind one
another, or when an appliance is separated by a separate air duct.
-
The induction appliance must not be placed near or on hot surfaces.
-The appliance is equipped with a filter. Regardless of this filter, make sure that grease from other
activities do not get onto the induction appliance (for example from nearby fryers or hot plates).
-The temperature of input air must be less than +35°C.
-
Personnel that use the appliance must ensure that installation, maintenance and checks are carried out only by qualified
staff.
Attention! In accordance with international rules, when connecting the appliance, an automatic device enabling the
disconnection of all contacts from the mains, must be installed above it; this device must have a contacts opening of at
least 3 mm.
Installation must be carried out observing the following norms:
- Safety prescription in force
- Installation prescription, norms in force.
The appliance is supplied without the connection cable. To install the power supply cable, proceed as follows:
•
Disconnect the power supply.
•
Remove the bottom panel
•
Push the connection cable through the cable blocker, connect the conductor wires to the corresponding terminals in
the junction box and fix them into place.
•
Block the cable with the cable blocker, and reassemble the bottom panel. The earth wire must be longer than the
others so that if the cable blocker should break, it will disconnect after the tension wires.
N.B. The connection cable must have the following characteristics: it must be at least the silicone type (resistant to a
temperature of at least 180°), and must have an adequate section for the power of the appliance (see technical data
table).
The appliance must be connected to an equipotent system. The connection screw is positioned at the back of the
appliance and is identified by the
Attention! The manufacturer will neither be held responsible for, nor will give any compensation during the guarantee
period for any damage caused, and which is due to inadequate installations not compliant with the instructions.
Indication
each plate is connected to a power adjuster which lets you choose from minimum temperature,
indicated on the knob by the number 1, and the maximum temperature, indicated by 6. For initial
cooking the highest temperatures are advised.
- each plate is equipped with a temperature limiter which activates when the current temperature may
damage the glass (see the paragraph "what to do in case of problems").
Warning
use only suitable pans (with ferrite bottom).
INDUCTION GENERATORS ARE A COMPONENT AND ARE NOT A COMPLETE, FINISHED MACHINE.
Fields of use.
Induction generators can be installed in fitted hobs and free-standing cookers and should be used for cooking, heating,
keeping things warm and roasting.
All the specific saucepans recommended for use for induction cooking can be used with induction generators, such as
saucepans in iron. Induction generators should not be used to heat objects other than those listed above.
GB
LAWS, TECHNICAL RULES AND NORMS
ELECTRIC CONNECTION
EQUIPOTENTIAL
symbol.
INDUCTION GENERATOR