Checking Primary Air In Main Burners; Burners" Technical Data Table; Rules For Converting And Installing For Other Types Of Gas; Substituting The Nozzle In Open Cooking Rings - Lotus TPT-64G Instructions Pour L'installation Et L'emploi

Cuisieneres avec four usage professionale
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

All the burners are provided with an air regulator which, by means of a bush, can be regulated and fixed with a screw,
enabling the variation of primary air. In the "Burners technical data" table are the approximate values of parameter "h"
(primary air) (see page 3 fig. 3). The volume flow of primary air must be regulated so that the flame does not tend to
come away from the burner when it is cold or backfire when the burner is hot.
Burner max 3,5 KW-min 1,2kW
Burner Injector 1/100 mm
Min. output adjustment 1/100 mm
Consumption
Primary air h=mm
Burner max 5,5 KW-min 1,8kW
Burner Injector 1/100 mm
Min. output adjustment 1/100 mm
Consumption
Primary air h=mm
TP Burner max 5,5 KW-min 2,6 kW
Burner Injector 1/100 mm
Min. output adjustment 1/100 mm
Consumption
Oven burner max. 4 kW -min 1,15 kW
Burner injector 1/100 mm
Min. output adjustment 1/100 mm
Consumption
Primary air h=mm
Grill burner max 4 kW
Burner injector 1/100 mm
Consumption
Primary air h=mm

RULES FOR CONVERTING AND INSTALLING FOR OTHER TYPES OF GAS

Our appliances are tested and regulated with liquid gas (see data plate).
The conversion or adaptation to another type of gas must be carried out by a specialized technician. The nozzles for the
various types of gas are supplied in a packet and are marked in hundredths of mm (see "burners" technical data table).

SUBSTITUTING THE NOZZLE IN OPEN COOKING RINGS

Remove the grills, the burners and the containers, substitute the nozzles with the right ones, using a suitable spanner,
unscrewing the blockage screw and relative jam nut. After regulating, screw back the screw and the jam nut, regulate
minimum output by turning the screw to the right or to the left until the thermal power reaches 1,2 KW for the burner of
3,5 KW, and 1,8 for the burner of 5,5 KW.
Warning: For functioning with liquid gas, the screw for regulating minimum output must be blocked completely.

SUBSTITUTING THE NOZZLE IN THE ALL PLATE BURNER

Remove the panel and with a suitable spanner substitute the nozzle with another, suitable one.
Adjust the minimum flame by turning the by-pass screw either to the right or to the left until heat output reaches 2,6
kW.
The primary air of the all plate burner does not need adjusting.
Attention: If liquid gas is used, the minimum flame adjustment screw must be screwed right down.
To change the oven nozzle proceed as follows:
Remove the bottom oven panel;
Unscrew both securing screws from the burner (see Fig.E), pull it out and unhook it,
GB

CHECKING PRIMARY AIR IN MAIN BURNERS

"BURNERS" TECHNICAL DATA TABLE

12.8 kwh/KG
G30
BUTANE
30 mbar

CHANGING THE OVEN BURNER NOZZLE

IE
IT
CH
12.8 kwh/KG
G31
PROPANE
37 mbar
93
60
0.273 kg/h
0.273 kg/h
27
117
70
0.43 kg/h
0.43 kg/h
27
120A
120A
85
kg/h 0,430
kg/h 0,427
102
50
kg/h 0,312
kg/h 0,312
7,5
102
kg/h 0,312
kg/h 0,312
7,5
42
3
9.45 kwh/m
st.
G20
NATURAL GAS H
20 mbar
93
145
60
adjustable
3
0.37 m
st./h
27
14
117
180
70
adjustable
3
0.582 m
27
14
170A
85
adjustable
3
m
st./h 0,582
102
160
50
adjustable
3
m
st./h 0,423
7,5
6
102
160
3
m
st./h 0,423
7,5
6
st./h

Publicité