OPERATION | INSTALLATION

Technical Data

5.
Technical Data
Voltage
Wattage, max.
Amperage, max.
Phase
Frequency
Type of installation
Internal cylinder material
Enclosure material
Thermal insulation material
Color
Nominal water volume
Standby heat loss
Recovery time
Temperature setting range
Maximum operating pressure
Weight empty
Water connections
Dimensions and connections
280 (11")
140 (5.5")
c06
c01
c01
Cold water inlet
c06
Hot water outlet
6.

General Recommendations

The installation must be carried out by licensed profes-
sionals. All state and local codes must be adhered to.
The manufacturer will not be liable for any damages be-
cause of failure to comply with these installation instruc-
tions or because of improper installation performed by
an unqualifi ed installer.
www.stiebel-eltron-usa.com
SHC 2.5
V
110–120
W
A
Single, 1/N/PE
Hz
Under sink
Polystyrene
GAL / L
2.65
kWh / day
Minutes
°F / °C
86–140
PSI / MPa
150
Lbs / kg
15.9
1/2˝ NPT
270 (10.63")
80 (3.15")
100 (3.94")
SHC 2.5
1/2˝ NPT
1/2˝ NPT
Choose a location that allows easy access for mainte-
nance or servicing. The water heater should be installed
at least 8 – 9˝ from the ceiling or any adjacent walls.
233219
1300
7.

Mounting the Unit

11.3
NOTICE:
50/60
!
UNIT MUST BE INSTALLED IN A VERTICAL PO-
Steel
SITION WITH THE WATER FITTINGS POINTING
Plastic
UPWARD.
white
WARNING:
10
0.5
DO NOT INSTALL UNIT WHERE IT WOULD ROU-
18
TINELY BE SPLASHED WITH WATER. ELECTRIC
30–60
SHOCK MAY RESULT.
1.0
7.2
CAUTION:
HOT WATER OUTLET PIPES LEAVING UNIT CAN
BE HOT TO THE TOUCH. INSULATION MUST BE
USED FOR HOT WATER PIPES BELOW 36" DUE
TO BURN RISK TO CHILDREN.
NOTICE:
!
THIS UNIT SHOULD NOT BE INSTALLED IN A LO-
CATION WHERE IT MAY BE EXPOSED TO FREEZ-
ING TEMPERATURES (LESS THAN 36 °F [2 °C]).
IF THE UNIT MAY BE SUBJECT TO FREEZING
TEMPERATURES ALL WATER MUST BE DRAINED
FROM THE UNIT. FAILURE TO COMPLY WITH THIS
INSTRUCTION VOIDS ALL WARRANTIES.
THE UNIT SHOULD BE LOCATED IN AN AREA
WHERE WATER LEAKAGE FROM THE UNIT OR
CONNECTIONS WILL NOT RESULT IN DAMAGE
TO THE AREA ADJACENT TO THE UNIT. IF SUCH
A LOCATION CANNOT BE AVOIDED IT IS REC-
OMMENDED THAT A DRAIN PAN BE INSTALLED
UNDER THE UNIT.
1. Drill two (2) 1/4 inch holes in the wall where the
water heater will be mounted.
2. Install plastic wall anchors.
3. Fasten wall mounting bracket to the wall.
4. Hook water heater to the mounting bracket.
5. Pull downwards on the water heater to properly
seat it on the bracket.
SHC 2.5 |
5