Electrical Connection; 10. Settings - Stiebel Eltron SHC 2.5 Directives D'installation Et Mode D'emploi

Chauffe-eau électriques à mini-réservoir
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

OPERATION | INSTALLATION

Electrical Connection

7. Must not have a valve between the relief valve and
the tank.
FILLING THE WATER HEATER
To fi ll the water heater:
1. Open the hot water faucet.
2. Open the cold water supply valve.
3. When water runs out of the faucet, the tank is
fi lled.
4. Close the hot water faucet.
5. Check entire system for leaks.
9.
Electrical Connection
CAUTION:
!
NEVER PLUG THE WATER HEATER'S CORD INTO
AN ELECTRICAL OUTLET UNLESS IT IS FILLED
WITH WATER. OTHERWISE, THE UNIT WILL GET
DAMAGED BEYOND REPAIR.
NOTICE:
THE WATER HEATER MUST BE CONNECTED TO A
GROUNDED OUTLET.
THIS WATER HEATER WAS DESIGNED FOR USE
AT 110 - 120 V. DO NOT USE THIS WATER HEAT-
ER WITH ANY OTHER VOLTAGE. FAILURE TO USE
THE CORRECT VOLTAGE MAY RESULT IN PER-
SONAL INJURY OR PROPERTY DAMAGE.
THE HEATER IS SUPPLIED WITH AN ELECTRICAL
CABLE WITH A PLUG. IF THE CABLE IS DAMAGED
OR LENGTH NOT SUFFICIENT, IT MUST BE RE-
PLACED BY A LICENSED ELECTRICIAN.
To be certain that all the air is out of the system, open
the hot water faucet on your fi xtures until constant water
fl ows from them. Otherwise, damage to the element
may occur.
Connect the water heater to a GROUNDED OUTLET.
The unit is fi tted with a power cord to connect the water
heater to a receptacle. State and local codes must be
adhered to. Install the correct breaker at the circuit
breaker panel.
The water heater was manufactured and wired in ac-
cordance with the UL requirements.
A temperature high limit with manual reset has been
factory installed to interrupt the power supply in the
event of a thermostat failure.
www.stiebel-eltron-usa.com
DO NOT use this water heater with any other voltage.
Failure to use the correct voltage may result in personal
injury or property damage.
Electrical diagram
4
3
1
2
1
A
L
1. Thermostat
2. Cut-off
3. Lamp indicator
4. Heating element
5. Tank

10. Settings

The water heater is equipped with an adjustable ther-
mostat that automatically controls water temperature.
The indicator lamp remains lit only when the water is
being heated.
The temperature is adjusted by turning the knob coun-
terclockwise (to the left) to increase the temperature
and clockwise (to the right) to decrease the temperature.
The water heater thermostat can be set to guard against
freezing. This position keeps the internal temperature
above the freezing point.
Freeze protection setting
2
5
B
N
PE
SHC 2.5 |
7

Publicité

Chapitres

Table des Matières
loading

Table des Matières