Remote Control; Schedule For User's Program - LK Armatur SmartComfort RTW Manuel D'instruction

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 12
GB
ENGLISH
Creating user programs U1 and U2
With
U1
and
U2
you can create your own program. The time step
is 30 minutes. Each time a value or symbol blinks, you can make a
choice with the (+) or (-) keys. Once the choice is made press
go to the next step. You can at any time cancel a setting by pressing
.
Select program mode P. Then select user program
or (-) keys. Press the edition key
programming starts 00:00 and ends 24:00.
blinks and the display shows 01. Select desired mode
or
with (+) or (-). Press OK. In this example select
The time 00:00 blinks and the display shows 01A. With (+) or
(-) you set the time when the reduced temperature should start
this day e.g. 00:00. Press OK.
The time 00:30 will blink and the display shows 01b. With the
(+) or (-) keys you set the time when the reduced temperature
should fi nish, 06:00. Press OK. The temperature blinks. Set the
desired reduced temperature, 20°C. Press
blinks and the display shows
press
OK.
In this example select
display shows
02A.
With the (+) or (-) key you select the time when
the reduced temperature should start, 09:00. Press
The time 09:30 will blink and the display shows
(-) keys you select the time when the reduced temperature should
fi nish, 16:00. Press
OK.
The temperature blinks. Select the desired reduced temperature
18°C and press
OK.
In this way further settings can be made. Max. settings a day are
5 periods.
When you are fi nished programming press the edition key
the display will show
Copy Yes.
Now you can choose to copy the day program just created to sub-
sequent days. The program creation will always start with day
1=First day of the week. Press
following day.
If you don't want to copy the program, change the choice
to
Copy no
with the (+) or (-) keys and confi rm your choice with the
OK
key. You will now be invited to create a new program for the
following day.
When you press
OK
on the last day 7, you will be invited to save
your program. The message
blinks. Press
OK
to save your program.
user program
U1
are now shown on the display.
The program you now have created has comfort temperature from
06:00 – 09:00 and 16:00 – 24:00.
Reduced temperature
Reduced temperature
Service Mode
The room temperature unit has a menu to change the parameters.
In order to enter this menu press and hold the edition key
10 seconds.
Note that the clock setting mode is fi rst shown. Hold the
down until the service menu is displayed.
Now you can select a parameter with the navigation keys
. Modify the value with the (+) and (-) keys and press OK. To
leave the parameter menu, choose parameter
6
U1
with the (+)
to create a new program. The
OK.
02.
Select the desired mode and
.The time 06:00 blinks and the
OK.
02b.
With the (+) or
OK
and copy the program to the
SAVE
appears and the green LED
Auto
operating mode and
, 20°C, 00:00 – 06:00
, 18°C, 09:00 – 16:00
99 End
and press OK.
Keyboard's Lock Function
This function prevents unauthorized changes of your settings.
To activate the keyboard's lock function, press and hold
OK
to
and
simultaneously.
Repeat the same procedure to unlock the keyboard
Airing
If the room unit detects a sudden drop in temperature the unit will
disregard this for the next half hour. Decimal point and tempera-
ture unit blink.

Remote Control

.
By connecting a GSM modem to the room unit, it can be remote
controlled e.g. via mobile phone. Please, see No. 12 under Param-
eters and Functions. It may take some time before the symbol ap-
pears. If a temperature setting or the operating mode in the room
unit is changed, the remote control will be interrupted. Note! Only
a voltage- and potential-free contact is to be connected to the ter-
minal block on the back of the room unit.
Trouble Shooting
Note that when a temperature setting has been changed it will take
hours before the room temperature corresponds to the new setting
due to dimensions of the heating system and insulation of the house.
If the room temperature unit works but the room temperature is
not in accordance with the program:
Check the time setting
Check that the program step is not too short
Check that the difference between comfort and reduced
temperature is not too high
and
Otherwise do the trouble shooting according to the list in the
LK 110/LK 120/LK 130 SmartControl Instruction Manual.
Error codes -
10
Internal error
11
Supply temperature sensor
12
Outdoor sensor
Copy Yes
13
Reserve
14
Room temperature unit, communication error
15
Reserve
50
Room temperature unit, room temperature sensor

Schedule for user's program

:
:
:
:
:
:
:
:
:
:
for
:
:
key
:
:
or
:
:
:
:
will now appear on the display.
Shown on the display:
° C
1 2 3 4 5 6 7
° F
° C
1 2 3 4 5 6 7
° F
° C
1 2 3 4 5 6 7
° F
° C
1 2 3 4 5 6 7
° F
° C
1 2 3 4 5 6 7
° F
° C
1 2 3 4 5 6 7
° F
° C
1 2 3 4 5 6 7
° F
° C
1 2 3 4 5 6 7
° F
° C
1 2 3 4 5 6 7
° F
March
15

Publicité

Table des Matières
loading

Table des Matières