INSTALLATION
GB 26
between connecting points 3-4. The groups must have fuses
of at least 16 A (2x). The core diameter of the connecting cable
must be at least 2.5 mm
generators left
generators
right
4
3
2
Special connection:
• Single phase connection (1L 1N, 230 V ~ / 50 Hz):
▷ The voltage between the phase and the zero is 230 V ~. Fit a
connecting bridge between connecting points 1-2 and 3-4. The
group must have a fuse of at least 32 A. The core diameter of
the connecting should be at least 6 mm
generators left
generators
right
4
3
2
The bridges on the connecting block can be used to create the required
connections, as indicated in these illustrations.
Fix the cable with the pull relief and close the cover.
Connection point, wall-mounting socket and plug must be accessible
at all times.
2
.
appliance
internal
1
appliance
internal
1
2
.