INSTALLATION
Installation dimensions
inside the cabinet
x<46 mm: y = 46 mm - x
x>= 46 mm: y = 0 mm
B
C
A
Installation dimensions
The dimensions and recesses are shown in the illustration beneath.
If the hob is wider than the cupboard, with a worktop less than 46 mm
thick, saw a cut-out in both sides of the cupboard, so the appliance is
detached from the cupboard.
600
Ventilation
The electronics in the appliance need cooling. The appliance will
automatically switch off if there is insufficient air circulation. There
are ventilation openings on the underside of the appliance. It must be
possible for cool air to be drawn in through these openings. There are
outlet openings on the underside and at the front of the appliance.
Constructing above a load or an oven or fixed pannel
Ventilation occurs through the plinth (A) and the back of the cupboard
(B). Saw out the ventilation openings (min. 100 cm
necessary if there is another opening that can supply air together with
opening B.
Y
X
Y
2
). Air supply A is not
GB 23