TERMINAL BOARD CONNECTIONS
17-18 LC/ELS Courtesy light output 24 Vdc 15 W or output for a 12V
electric lock. Selection is carried out using DIP 6.
19
CMN common for all inputs and outputs.
LAMP 24 Vdc 25 W output for warning lights, intermittent
20
activation (50%), 12,5 W continuous activation.
21
Output powering external loads 30 Vdc
Controlled output, powering external loads 30 Vdc
22
23-24 CMN common for all inputs and outputs.
25-26 CMN common for all inputs and outputs.
27
FTCI (N.C./8.2 kΩ)
safety and control devices in input (photo-
(2)
cells invert the travel direction when an obstruction is detected).
Opening this contact will provoke a travel direction inversion
during closure due to the cutting in of the safety device.
TB (N.C./8.2 kΩ)
28
stop button input (The opening of this con-
(2)
tact interrupts the cycle until a new movement command is
All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law
given).
TD (N.O. contact) sequential command button input
29
30
CSP (N.C./8.2 kΩ)
safety edge input (The opening of this
(2)
contact interrupts the cycle both in the closing stage as well
as in the opening stage).
31-32 CH2 (N.O. potential free contact) for the second radio channel
33
Power output 0 Vdc for the digital safety edge
Power output 12 Vdc for the digital safety edge
34
35
CSPF Signal input from the digital safety edge
36
Outer conductor for radio receiver antenna
37
Inner conductor for radio receiver antenna (if an external
antenna is fitted use a coaxial type cable RG58 with an imped-
ance of 50Ω).
EMRG1
38
(N.O. contact) emergency manoeuvre input 1
(4)
39
EMRG2
(N.O. contact) emergency manoeuvre input 2
(4)
40
CMN common for the emergency buttons
Note
The total of the 2 external device outputs must not exceed 5W.
(1)
F1
F2
F5
C2
C1
M2
M1
9
10
11
12
13
14 15
L1
ENCODER
Collegamento encoder a 4 fili
Connecting 4-wire encoder
Branchement encoder à 4 fils
Anschluss der Encoder mit 4 Drähten
Conexionado encoder con 4 conductores
B1
Signal buzzer "via radio" mode
C1
Battery connection NiMH
C2
Transformer secondary connection
C3
Battery charger connection
CSER Serial connection (only for diagnostics)
D1
Six-segment LED display
DS1
Selection dip-switch
EM
Emergency manoeuvre enable
F1
Fuse 3,15AT (230 Vac circuit protection)
F2
Fuse 10A (motor power supply protection)
F3
Fuse 10A (motor power protection during battery operation)
(1)
(1)
(3)
(3)
(3)
L2
F3
F4
16
17
18
19
20
21
22
23
24
COLORE
CABLAGGI
BLUE
Blu
GREEN
Verde
GREY
Grigio
YELLOW
Giallo
Note
The contact selection (N.C. or 8.2 kΩ) is carried out on the six
(2)
digit display (parameter "SC").
Note
The special safety edge is disabled by default; to enable the
(3)
function set the parameter "CSPF" to "1" in the menu.
Note
These inputs are disabled by default; to enable the functions
(4)
cut the two contacts "EM".
ALL UNUSED NC CONTACTS MUST BE BRIDGED and consequently
the security device test must also be deactivated (TFTC – DIP 5). If you
want to activate the FTCI test both the transmission and receiver parts
of the photocell must be connected to the binding post marked "CTRL
30 Vdc". If the test is active there will be a 1 second delay between the
command transmission and movement of the door.
Switch on the power and make sure that the indicator LEDS are in the
following condition:
- L1 Wrong battery connection
- L2 Power on
- L3 Digital safety edge activity
- L4 Indicates transmitter code programming
- L5 Indicates active inverting photocells "FTCI"
- L6 Indicates active blocking button "TB"
- L7 Indicates active safety edge "CSP"
- L8 Indicates digital safety edge "CSPF"
- L9 Indicates active digital command "TD/CH1"
Note
If this LED is "lit" invert the battery power cables immediately.
(5)
Note
This LED is "lit" if the digital edge is connected and at rest.
(6)
Note
(7)
The LEDS are "lit" when the relative safety device is inactive.
Check that the activation of the safety devices (those which have
not been bridged) switch the corresponding LEDS off. If the green
power on LED "L2" doesn't light up check the condition of the fuses
and the power cable connection at the transformer. If one or more
of the safety LEDS do not light up check the contacts of
security devices and check that the unused safety device contacts
have been bridged.
C3
31
J2
J1
P2
L3
MM
R1
CH2
25
26
27
28
29
30
31
32
33
CABLE COLOUR
COLORATION
CODE
DES CÂBLAGES
Blue
Bleu
Green
Vert
Grey
Gris
Yellow
Jaune
F4
Fuse 4A (24V circuit protection during battery operation)
F5
Fuse 4A (24V circuit protection)
J1
Jumper enabling remote transmitter memorisation
Second radio channel selection jumper
J2
MM
Transmitter code memory module
P1
Programming button (PROG)
P2
Transmitter code cancellation button (DEL)
P3
Transmitter code memorization button (MEMO)
P4
Dynamic button "TD"
P5
Blocking button "TB"
R1
Radio frequency module, 433 MHz for S449 transmitters
23
P1
P3
L4
D1
L9
L7
L6
B1
L5
36 37
38 39 40
34
35
DS1
EM
KABEL-
COLORACIÓN
FARBEN
CABLEADOS
Blau
Azul
Grün
Verde
Grau
Gris
Gelb
Amarillo
off
(5)
lit
off
(6)
off
lit
(7)
lit
(7)
lit
(7)
lit
(7)
off
the relative
P4
L8
P5
ELS
TFTC
LP
1MOT
RA
TD

Publicité