IMPORTANT REMARKS

READ THE FOLLOWING REMARKS CAREFULLY BEFORE PROCEEDING WITH THE INSTALLA-
TION. PAY PARTICULAR ATTENTION TO ALL THE PARAGRAPHS MARKED WITH THE SYMBOL
NOT READING THESE IMPORTANT INSTRUCTIONS COULD COMPROMISE THE CORRECT WORK-
ING ORDER OF THE SYSTEM AND CREATE DANGER SITUATIONS FOR THE USERS OF THE SYSTEM.
• These instructions are aimed at professionally qualified "Installers
of electrical equipment" and must respect the local standards and
regulations in force.
All materials used must be approved and must suit the environment in
which the installation is situated.
• All maintenance operations must be carried out by professionally
qualified technicians. Before carrying out any cleaning or maintenance
operations make sure the power is disconnected at the mains.
• This appliance must be used exclusively for the purpose for which it
has been made. "i.e. The automation of garage doors". Any non
authorised modifications are to be considered improper and therefore
dangerous.
USE
The appliance may be used to operate overhead garage doors.
For garage doors with a width of over 4 m and not more than 2,7 m in
height and for garage doors with a pedestrian access door two motors
are required (one "master" motor with on board electronics 310/GLB249M
and one "slave motor" without 310/GLB249S).

IMPORTANT SAFETY INSTRUCTIONS

It is the responsibility of the installer to make sure that the following public
safety conditions are satisfied:
1) The pedestrian door must not open on its own, e.g.; swing open while
the garage door is in movement.
2) The appliance must not be operated when the pedestrian door is not
fully closed.
3) Make sure that there are no dangerous sharp edges.
4) Make sure that the end-user is aware that children and/or pets must
not be allowed to play within the area of a garage door installation. If
possible include this in the warning signs.
5) A correct earth connection is fundamental in order to guarantee the
electrical safety of the machine.
6) If you have any questions about the safety of the door operating system,
do not install the operator. Contact your dealer for assistance.
TECHNICAL DESCRIPTION
• Single piece geared reduction unit with an incorporated encoder and
manual release system.
• 24 V direct current drive motor.
• Reduction unit in pressed aluminium fitted with a reduction system
made out of materials that guarantee maximum efficiency and maximum
noise reduction.
• Handle operated manual release mechanism mounted directly on the
motor.
• Base in zinc-plated steel
• Carter in shock-proof plastic
• Incorporated 24 Vdc courtesy light protected by an opaque panel.
• Output for a 230 Vac external courtesy light located on the "Master"
motor.
• 310/GLB249M Motor with an incorporated electronic programmer
complete with power stage, logic control, (optional battery charger)
and radio receiver.
Power is rooted to the card by a separate toroidal transformer housed in
the same container and connected to the card. Incorporated "TD" and
"TB" manoeuvring buttons, visualisation via LED display, fuse checking
and replacement access port.
Access for function setting and radio control transmitter programming
and cancellation.
• 310/GLB249S motor without on board electronics.
IMPORTANT REMARKS
ACCESSORIES
316/GLO2AD
316/GLO3A
316/GLO4A
316/GLO6A
316/GLOPS2
316/GLOTG
316/GLOCGL - Ferrule and DIN threaded pin, with pipe support brackets
316/GL24SB
PRG249BCN
USER INSTRUCTIONS
This symbol indicates that once the products life-span has
expired it must be disposed of separately from other rubbish.
The user is therefore obliged to either take the product to a
suitable differential collection site for electronic and electrical
goods or to send it back to the manufacturer if the intention is
to replace it with a new equivalent version of the same product.
Suitable differential collection, environmental friendly treatment and
disposal contributes to avoiding negative effects on the ambient and
consequently health as well as favouring the recycling of materials.
Illicitly disposing of this product by the owner is punishable by law and
will be dealt with according to the laws and standards of the individual
member nation.
During the opening/closing manoeuvre check for correct operation and
activate the emergency stop button in case of danger.
The appliance must not be activated in the dark therefore make sure that
the night lights function correctly.
The appliance can be manually released in case of emergency (see manual
release mechanism on page 21).
Periodically check the moving parts for wear and tear and grease if required,
using lubricants which maintain their friction levels unaltered throughout
time and are suitable for temperatures of -20 to +70°C. In case of failure
or operational anomalies switch off the power at the mains do not attempt
to repair the appliance yourself. Periodically check the correct operation of
all safety devices (photoelectric cells, safety edge etc.). In particular make
sure that the safety edge forces the door to invert travel direction and that
weights greater than 20 kg are not lifted.
Eventual repair work must be carried out by specialised personnel using
original spare parts. The appliance is not suitable for continuous opera-
tion and must be contained within the value stipulated (see technical data
on page 60).

INSTALLATION INSTRUCTIONS

The minimum controls which may be installed are SEQUENTIAL-STOP,
these controls must be installed at a height between 1,5 and 1,8 m an in
a location not accessible to children. Warning sighs or adhesive should
be placed near the commands indicating the points where the risk of
crushing exists.
Instruct the end user in the correct use of the manual release device and
apply permanent adhesives indicating that procedure near the device.
Before starting with the installation of the system check that the structure
which is to be automated is in good working order and respects the local
standards and regulations in force.
Automating an existing system which has sliding or balancing problems
will not solve those problems and may even make them worse by placing
more stress on weakened or damaged areas.
To this end make sure that the runner guides slide freely and grease all the
moving parts (pins, castors etc.) using lubricants which maintain unaltered
friction characteristics over a period of time and are suitable for tempera-
tures of -20 to +70°C.
19
IMPORTANT REMARKS
- Straight telescopic arm length 700 mm.
- Curved (right) telescopic arm length 700 mm.
- Curved (left) telescopic arm length 700 mm.
- Straight telescopic arm length 1000 mm.
- Extended support base (optional).
- Pair of pipes, pipe support brackets and DIN threaded
pins for central motor positioning.
for lateral motor positioning.
- Manual release cord.
- Kit battery charger + batteries.
Attention! Only for EU customers - WEEE marking.