GETTING STArTEd - PrEPArATION

wArNING: Always disconnect the saw from
the power source before making any adjustments.
This saw is equipped with an approved mains
lead and plug for its intended Country of use.
Do not alter or modify the mains lead.
(<10.1) INSTALLING/rEMOVING A BLAdE
wArNING: Only use genuine Evolution blades which
are designed for this machine. Ensure that the maximum
speed of the blade is compatible with the machine.
Only perform this operation with the machine
disconnected from the power supply.
Note: It is recommended that the operator considers wearing
protective gloves when handling the blade during installation
or when changing the machines blade. (>10.1)
• Place saw on a level, secure surface.
• Lock the machine arbor by engaging the arbor lock. (Fig. 1)
• Using the supplied Hex Key loosen and remove the arbor socket
headed screw, washer and outer blade drive flange. (Fig. 2)
Note: The socket headed arbor screw has a Right Hand thread.
Turn clockwise to tighten. Turn counter clockwise to loosen.
• Remove the saw blade, leaving the inner blade flange in its
service position.
• Thoroughly clean inner and outer blade drive flanges and
blade mounting surface before installing a new blade.
• Ensure that the direction of rotation arrows printed on the
blade, match the direction of the rotation arrows found on
the machines upper and lower guards. (Fig. 3)
• Reinstall the outer drive flange, washer and the arbor socket
headed screw.
• Engage the arbor lock and tighten the arbor socket headed
screw using the hex key.
• Check that the arbor lock is fully released by manually
rotating the blade.
• Check the operation of the lower blade guard
Fig. 1
Fig. 2
Fig. 3