Product and functional description,
Display, LED
Hygrostat control The dehumidifier can operate continuously or be controlled by a hygrostat. The
Illustration,
Connection of
hygrostat
22
The table gives an overview of the meaning of the LEDs:
Part
Function
ON/OFF
Condenser coil
temperature too
high
Temperature alarm
Full water container
Defrosting on
The evaporator is
iced up
hygrostat is supplied as an extra accessory.
continued
power is on
the condenser coil is higher than 55 °C and therefore
the unit has been switched off in order to protect the
compressor. After 44 minutes the unit switches on
again automatically. During these 44 minutes the LED
will light up in red to indicate a failure.
the room temperature is lower than 3 °C.
The unit is switched off
When the temperature is higher than 3 °C, the unit
switches on again automatically
the unit is switched off because the water container is
full.
CDT 85:
has no LED as this model has no water container.
the evaporator coil is being defrosted. During
defrosting the compressor is working and the fan is
stopped.
the room temperature lower than approx. 15 °C the
evaporator will ice up. The defrost function allows icing
up for 44 minutes before defrosting of the evaporator
coil is activated
Part
Fig. 15
Illuminates when...
Function
Hour meter
Main switch
Switch for heating element (only
CDT 35S)
Hygrostat socket (accessory)
Cable entry
Continued overleaf