General

Please read these instructions and observe their contents and
warnings before assemble the equipment!
Intended use
WGM Top is a sun protection awning that can primarily be used for this
purpose. WGM Top can be used as rain protection contingent on the inst-
ructions for controlled rain drainage*. Misuse of the awning, as well as any
alterations, changes or additions to the awning that are carried out without
weinor's written permission can lead to damage, hazards or the collapse
of the awning. These are not permitted and will result in the voiding of the
guarantee claims.
(* Use of the WGM Top as rain protection only under supervision and only
when the rain drainage is guaranteed to prevent damage to the system due
to pooling in the fabric. If the awning fabric is retracted while still wet, mould
and stains may form! Only retract a wet awning in the event of an emergency
(e.g. with the risk of a storm, frost or snowfall)! Wet fabric must be dried out
as quickly as possible when the awning is open!)
CE mark
Weinor GmbH & Co. KG declares that the WGM Top
is in compliance with the basic requirements and
relevant provisions of the EN standards. WGM Top
meets the requirements of the wind resistance class in-
dicated in the CE conformity marks. The requirements
shall only be deemed as having been met once the
manufacturer's instructions have been adhered to.
Qualifications
These instructions are addressed to trained fitters and require qualification
and knowledge of installation techniques:
- Occupational safety at work, operating safety and accident prevention
regulations
- Handling of ladders, scaffolding, tools and machines,
- Transport of long, heavy components and glass panes,
- Estimation of the building structure and fitting the fixing materials,
- Installation, start-up and operation of the product.
Employ a professional installation company if you do not possess these
qualifications!
Safety symbols
Warning! Risk of electric shock!
Careful! Personal injury!
Caution! Product and property damage!
Safety instructions
Warning! Risk of electric shock!
Electrical fixed installation may only be carried out by electrically skilled
person according to VDE 100!
Observe the installation instructions for the electrical devices included in
the delivery!
Separate the electrical connections from the mains during the installation!
Only connect electrical termination to mains system with all-pole discon-
necting device and with min. 3 mm contact opening width!
Only connect the construction if indications on product relating to voltage,
frequency and output match those of the power source!
Caution! Personal injury!
Follow safety instructions in order to prevent personal injury!
Observe the instructions for installation and setting from the manufactu-
rer of the drive, commutator and control!
Keep packaging, sheeting and small parts away from children (choking
hazard)!
Technische Änderungen vorbehalten | Technische wijzigingen voorbehouden | We reserve the right to make technical changes | Sous réserve de modifications techniques
Disconnect current supply when working within the movement range of
the construction (disconnect connector coupling on driver or install cont-
rolled power interruption from the outside)!
Switch off fuses and automatic control in order to prevent risk of crushing
or falling due to uncontrolled movements of the construction!
If awnings are operated by several users: a priority locking device must
be activated (controlled interruption of the power supply from outside),
making it impossible to open or retract the awning at all!
Ladders:
Do not lean ladders against the awning or fix them to the awning!
Ladders must be on a firm base and provide adequate support!
Only use ladders with adequate load-bearing capacity!
Anti-fall guards:
Use appropriate anti-fall guards to prevent the danger of falling especially
when working at considerable heights!
Mounting brackets:
Check that the type and number of the mounting brackets supplied are
compliant with the order!
Check that the information provided in the order about the installation
Weinor GmbH & Co. KG
surface tallies with the actual installation surface on site! Installation is
Mathias-Brüggen-Straße 110
50829 Cologne (Germany)
inadmissible in case of safety-relevant deviations!
17
EN 13 561
Fixing material:
Awning for use in exterior
area
Use suitable installation and fitting materials (plugs, glue, etc.) correspon-
Wind resistance class:
Class 3
ding to onsite conditions and loads! In doing so, the extraction forces
specified by the manufacturer must be observed and taken into account!
The awning must be fitted with the type and number of brackets recom-
mended by the manufacturer.
Crushing and cutting zones:
Crushing and shearing zones exist between movable components and
moving awning parts (projection profile, housing, folding arms, profiles)
which could catch and draw in clothing or body parts!
Only activate awnings up to 2.5 m installation height if the moving parts
are within your line of vision! Electrical controls, radio controls with latch
switches, stand-alone latch switches, etc. are not permissible in this case!
The key switch must be fitted in the line of vision of the projection profile,
but far enough removed from the movable parts, at a height of 1.5 metres
(national regulations relating to disabled people must be observed)!
Partly mounted awnings:
In awnings which are partly mounted in the factory, secure the spring-
Danger level III
tensioned parts (designated by the manufacturer) against unintentional
opening.
Danger level II
Caution! Do not remove this locking device until the installation of the
awnings has been completed in order to prevent the high risk of injury
Danger level I
that could result from unintentional opening of spring-tensioned parts!
Test run:
When ascending the awning for the first time, make sure that the working
range of the awning and the area below it is kept clear!
A visual inspection of the fixing material and brackets must be performed
after the awning has been extended for the first time.
When carrying out test runs, never use automatic system control or swit-
ches if the awning is not in the operator's line of vision!
Use test cable for the motor input!
Caution! Product and property damage!
Secure cargo properly and safely!
Protect the packaging from moisture (dampened packaging can come
loose during transport)!
Seal open packaging for further transport!
The awning must be carried to the place of installation the right way
round so it does not have to be turned round again in a confined space.
Raising the awning to a higher level using ropes:
Remove awning from the packaging and secure tightly with hauling
ropes!
Lift the awning horizontally and evenly!