Installation and Operating Instructions
RX TI RB Runback Timer
1. Description
The runback timer allows the heater to be operated for a
preset period of time. Depending on the presetting, the
timer switches off after the preset time period has elapsed
(standard mode), or else switches to another operating
mode (comfort mode). The settings that can be selected
range from 0.5 – 4 hours (in 0.5-hour increments).

1.1 Standard Mode

The heater is switched on for a preset operating time im-
mediately after the Start button has been pressed. The
room temperature is regulated in accordance with the
thermostat setting on the heater. After the preset time pe-
riod has elapsed, the timer switches the heater off. If re-
quired, the program can be reactivated by pressing the
Start button.

1.2 Comfort Mode

The heater is switched on for a preset operating time im-
mediately after the Start button has been pressed. The
room temperature is regulated in accordance with the
thermostat setting on the heater. After the preset time has
elapsed, the timer switches to the setback mode and low-
ers the room temperature set on the thermostat by 5 ° C for
the next 24 hours. After these 24 hours have elapsed, the
frost protection setting is active. The thermostat of the
heater regulates the room temperature to a value of
5 ° C. This setting is maintained.
2. Setting the Timer
Before the runback timer is installed, the heater operating
time and operating mode must be set. Four miniature
switches are arranged in a recess on the underside of the
cassette for this purpose.
2.1 Setting of the Standard mode
Select a heater operating time and set the miniature
switches in accordance with the chart.
1
ON
DIP
1 2
3
4
2
3
4
Heating period
0,5 hour
1 hour
1.5 hours
2 hours
2.5 hours
3 hours
3.5 hours
4 hours
2.2 Setting the Comfort Mode
Place switch 1 to the up position. Select a heater operating
time and set the miniature switches accordingly.
2. Installation
Turn off heater and carefully tilt it toward the front. With a
flat-blade screwdriver push latching clip of cover in the di-
rection of the arrow and remove cover. Slide cassette all
the way into the opening.
4. Start-Up
Switch on heater and set
thermostat to the desired tem-
perature.
Press the Start button. The
heater is now operated for the
preset time period (in the de-
sired operating mode).
The indicator light is illuminated while the preset time pe-
riod elapses.
5. Operational Performance in the Standard Mode
After the preset time period has elapsed, the timer
switches off. The program can be restarted by pressing the
Start button. If you wish to prematurely terminate the pre-
set program, press the Start button. The heater is switched
off.
6. Operational Performance in the Comfort Mode
After the preset time period has elapsed, the timer auto-
matically switches the thermostat to a temperature which is
5 ° C below the thermostat setting (setback mode). T he
heater will then maintain this temperature for another 24
hours. At the end of these 24 hours, the timer switches the
thermostat to the frost protection temperature at approx. 5
° C (frost protection setting).
Pressing the Start button allows you to move to the next
operating mode, i.e. from the normal to the setback mode,
from the setback to the frost protection mode, from the
frost protection mode back to the normal mode.
11
3
1
2
4
Heating period
0,5 hour
1 hour
1.5 hours
2 hours
2.5 hours
3 hours
3.5 hours
4 hours
Start button – Indicator light

Publicité