84
AVENTICS | CL03/CL03-XL | R402000141–BDL–001–AE
Commissioning
7
Commissioning
Commissioning may only be carried out by qualified
electrical or pneumatic personnel or an instructed person
under the direction and supervision of qualified personnel
(see "Personnel qualifications" on page 60).
7.1
Manual override
The manual override is a rotary switch. Do NOT press!
The valve control's functional reliability and method of
operation can be checked before start-up by activating the valve
positions using the manual override instead of the electrical
signal. The electrical signal is disabled when the manual
override is used.
7.1.1 Turn and detent (yellow knob):
O
Insert a screwdriver blade in the slot of the manual override
and turn it from position 0 to position 1 using slight force
until it clicks into place. See Fig. 12.
The valve switches and remains in the switched position until
the manual override is turned back to position 0.
7.1.2 Turn and release (red knob):
O
Insert a screwdriver blade in the slot of the manual override
and turn it from position 0 to position 1 using slight force.
The valve switches.
The valve returns to position 0 when released.