AVENTICS | CL03/CL03-XL | R402000141–BDL–001–AE
"Technical Data". See page 99.
Three different options for pilot supply are offered (see Fig 16):
W
Pilots supplied internally through channel 1.
The indicator dot (4) will then be in position 1-X.
W
Pilots supplied internally through channel 5.
The indicator dot (4) will then be in position 5-X.
W
Pilots supplied externally through port X in the end plate.
The indicator dot (4) will then be in position X.
Only an external supply is available for the end plate with
additional ports 3 and 5. The end plate must be exchanged
if the system is changed to an internal supply.
Fig. 16: Pilot air supply
8.4.1 Changing pilot air supply
1. Undo the two hex head screws (1) with a 7 mm wrench and
remove the cover (2).
2. Place the seal (3) in the desired position by turning it so that
the indicator dot (4) is in the correct position.
3. Replace the cover (2) and tighten the two hex head
screws (1). Tightening torque 1.0–1.2 Nm.
Conversion and Extension
1
2
3
93
4