BWP 30HS - BWP 30HSD
12 Device information
1
Type and order code
2
Design
2.1
Defrosting
2.2
Nominal cylinder volume
2.3
Transfer area of the internal heat exchanger
ø
2.4
Sensor pipe
for external sensors
internal
2.5
Installation location
2.6
Cylinder material
2.7
Cylinder insulation
2.8
Cylinder nominal pressure
3
Operating limits
3.1
Operating limit heat source
3.2
Setting range domestic hot water in heat pump operation °C
4
Flow / sound
4.1
Air flow
4.2
External compression max.
4.3
Air duct connection length max.
4.4
Sound power level
2
4.5
Sound pressure level
5
Dimension/weight and filling quantities
5.1
Dimensions height (max.) x cross-section (max.)
5.2
Air duct connection diameter
5.3
Weight (empty)
5.4
Refrigerant R 134a/total filling weight
6
Electrical connection
6.1
Degree of protection
6.2
Connection voltage
6.3
Connection line approx. 2.7 m - 1.5 mm
6.4
Fuse max.
6.5
Power consumption heat pump cos
6.6
Power consumption supplementary electrical heating
6.7
Power consumption max.
6.8
Nominal power consumption heat pump at 60 °C
6.9
Power consumption of supplementary electrical heating W
6.10 Total power consumption max.
7
Hydraulic connection
7.1
Circulation pipe connection
7.2
Domestic hot water outlet connection
7.3
Cold water inlet connection
7.4
Internal heat exchanger connection
8
Performance values
8.1
Heating-up period from 15 °C to 60 °C
4
8.2
Mean heat output at 45 °C
8.3
COP (t) according to EN 255 at 45 °C
8.4
COP in accordance with EN 16147 cycle XL
8.5
Useful domestic hot water quantity
8.6
Stand-by energy consumption at 55 °C/24h
8.7
Stand-by energy consumption at 45 °C/24h
1. At temperatures under 8 °C ± 1 °C or -8 °C ± 1 °C, the heating element switches on automatically and the heat pump module switches off.
2. At a distance of 1m (free-standing installation or installation without exhaust air duct or 90° pipe bends on outlet side).
3. Heating up of the nominal volume from 15 °C to 60 °C at an air intake temperature of 20 °C and 70 % relat. humidity
4. Heating up of the nominal volume from 15 °C to 45 °C at an air intake temperature of 15 °C and 70 % relat. humidity
EN-14
litre
2
m
mm
bar
1
°C
3
m
/h
Pa
m
dB(A)
dB(A)
mm
mm
kg
(kg)
2
A
A
A
A
3
W
W
external thread
external thread
external thread
external thread
3
h
W
l
kWh
kWh
451903.66.11 · FD 9401
BWP 30HS
no
290
1,45
12
frost-free
Enamelled steel according to DIN
4753
PU with foil cladding
10
8 to 45
± 1.0 K
23 to 60
400 - 550
100
10
60
50
1720 x 700
160
150
1,0
IP 21
1/N/PE~230 V, 50 Hz
With plug
C16
0,8
6,5
11,1
590
1500
2300
R 3/4"
R1"
R1"
R1"
8,5
1870
3,65
2,41
409
1,2
0,89
BWP 30HSD
yes
290
1,45
12
frost-free
Enamelled steel according to DIN
4753
PU with foil cladding
10
8 to 45
± 1.0K
23 to 60
400 - 550
100
10
60
50
1720 x 700
160
150
1,0
IP 21
1/N/PE~230 V, 50 Hz
With plug
C16
0,8
6,5
11,1
590
1500
2300
R 3/4"
R1"
R1"
R1"
8,5
1870
3,65
2,41
409
1,2
0,89
www.dimplex.de