WI 10TU - WI 22TU
12 Device Information
1
Type and order code
2
Design
2.1
Model
2.2
Controller
2.3
Thermal energy metering
2.4
Installation location / degree of protection according to EN 60 529
2.5
Performance levels
3
Operating limits
3.1
Heating water flow
3.2
Cold water (heat source)
4
Performance data / flow rate
4.1
Heating water flow at internal pressure differential
4.2
Cold water flow at internal pressure differential
1
4.3
Heat output / COP
2
4.4
Sound power level
4.5
Sound pressure level at a distance of 1 m
5
Dimensions / weight and filling quantities
5.1
Device dimensions without connections
5.2
Device connections for heating system
5.3
Device connections for heat source
5.4
Weight of the transportable unit(s) incl. packaging
5.5
Refrigerant / total filling weight
5.6
Lubricant / total filling quantity
6
Electrical connection
6.1
Supply voltage / fuse protection
Compressor
Primary circulating pump
shared feed compressor + primary circulating pump
6.2
Control voltage / fuse protection
6.3
Starting current with soft starter
6.4
Nominal power consumption W10/W35/max. consumption
Nominal current W10/W35/cos
6.5
7
Complies with the European safety regulations
8
Additional model features
8.1
Water in device is protected against freezing
8.2
Max. operating overpressure (heat source/heat sink)
1. These data indicate the size and capacity of the system according to EN14511. For an analysis of the economic and energy efficiency of the system, both the bivalence point and
the regulation should be taken into consideration.
The specified values, e.g. W10 / W55, have the following meaning: Heat source temperature 10 °C and heating water flow temperature 55 °C.
These specifications can only be achieved with clean heat exchangers.
Information on maintenance, commissioning and operation can be found in the respective sections of the installation and operating instructions.
2. The specified sound levels apply if the supporting feet (available as an option) are not used. If the supporting feet are used, the level can increase by up to 3db (A).
3. The specified sound pressure level corresponds to the operating noise of the heat pump in heating operation with a flow temperature of 35 °C. The specified sound pressure level
represents the free sound area level. The measured value can deviate by up to 16 dB(A), depending on the installation location.
4. Note that additional space is required for pipe connections, operation and maintenance.
5. flat-sealing
6. See CE declaration of conformity
7. The heat circulating pump and the heat pump manager must always be ready for operation.
EN-10
°C
°C
maximum (EN14511) m³/h/P
minimum
m³/h/P
minimum
m³/h/Pa
at W10/W55
kW/---
at W10/W45
kW/---
at W10/W35
kW/---
dB(A)
3 2
dB(A)
4
H x W x L mm
Inch
Inches
kg
type/kg
type/litres
A
1
kW
A/---
7
bar
452235.66.09 · FD 9506
WI 10TU
Universal
internal
Integrated
Indoors / IP 21
1
20 up to 62 ± 2
+7 to +25
1,7 / 5000
0,9 / 1400
2,2 / 6200
EN14511
8,4 / 3,2
9,1 / 4,3
9,6 / 5,9
41
30
845 x 650 x 665
5
G 1 1/4" external thread
5
G 1 1/4" external thread
142
R410A / 2.7
Polyolester (POE) / 1,2
3~/PE 400 V (50Hz) ; C10 A
3~/PE 400 V (50Hz) ; C10 A
3~/PE 400 V (50Hz) ; C10 A
1~/N/PE 230 V (50Hz) ; C13 A
17
1,63 / 3,2
2,94 / 0,8
6
yes
3,0
WI 14TU
Universal
internal
Integrated
Indoors / IP 21
1
20 up to 62 ± 2
+7 to +25
2,3/ 8000
1,1 / 1900
3,1 / 9200
EN14511
11,5 / 3,3
12,2 / 4,4
13,3 / 6,1
43
31
845 x 650 x 665
5
G 1 1/4" external thread
5
G 1 1/4" external thread
151
R410A / 3.3
Polyolester (POE)/1.2
3~/PE 400 V (50Hz) ; C10 A
3~/PE 400 V (50Hz) ; C10 A
3~/PE 400 V (50Hz) ; C10 A
1~/N/PE 230 V (50Hz) ; C13 A
20
2,18 / 4,3
3,93 / 0,8
6
yes
3,0
www.dimplex.de