Cabinet Dimensions
Cabinet opening dimensions shown are for 25" (64.0 cm)
countertop depth, 24" (61.0 cm) base cabinet depth and 36"
(91.4 cm) countertop height.
IMPORTANT: If installing a range hood or microwave hood
combination above the cooking surface, follow the range hood
or microwave hood combination installation instructions for
dimensional clearances above the cooktop surface.
Range may be installed with zero clearance to combustible
construction at the rear and on the sides below the cooktop.
B
C
A
E
F
J
I
K
L
A. 18" (45.7 cm) upper cabinet to countertop
B. 13" (33.0 cm) upper cabinet depth
C. 30" (76.2 cm) min. opening width
D. For minimum clearance to the top of the cooktop, see NOTE.
E. in U.S.A.: 30" (76.2 cm) min. opening width
in Canada: 31" (78.7 cm) min. opening width
F. 3" (7.6 cm) min. clearance from both sides of the range to the
side wall or other combustible material.
G. Cabinet door or hinges should not extend into the cutout.
H. 3" (7.6 cm) distance from wall
I. 1¹⁄
" (3.8 cm) min. from right side cabinet
2
J. 8" (20.3 cm) width
K. 7" (17.8 cm) min. from floor
L. 2" (5.1 cm) min. from floor
*Drill on centerline 1¼" (3.2 cm) from rear wall for gas supply
line.
**Gas lines must be installed within the shaded area to ensure
proper alignment of this oven with cabinets.
***Electrical plugs must be installed within the shaded area to
ensure proper alignment of this oven with cabinets.
NOTE: 24" (61.0 cm) minimum when bottom of wood or metal
cabinet is covered by not less than
millboard covered with not less than No. 28 MSG sheet steel,
0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or
0.020" (0.5 mm) copper.
D
G
H
8½"
(21.6 cm)
14"
(35.6 cm)
1½"
2¼" (5.7 cm)
(3.8 cm)
1¼"*
(3.1 cm)
8½" (21.6 cm)**
gas line location
⁄
" (0.64 cm) flame retardant
1
4
30" (76.2 cm) minimum clearance between the top of the
cooking platform and the bottom of an uncovered wood or metal
cabinet.
Electrical Requirements
IMPORTANT: The range must be electrically grounded in
accordance with local codes and ordinances, or in the absence
of local codes, with the National Electrical Code, ANSI/NFPA 70
or Canadian Electrical Code, CSA C22.1.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that
the ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
A 120 V, 60 Hz., AC only, 15 A, fused electrical circuit
■
is required. A time-delay fuse or circuit breaker is also
recommended. It is recommended that a separate circuit
serving only this cooktop be provided.
Electronic ignition systems operate within wide voltage limits,
■
but proper grounding and polarity are necessary. Check that
the outlet provides 120 V power and is correctly grounded.
The wiring diagram is located on the back of the range in a
■
clear plastic bag.
5