Télécharger Imprimer la page

Siemens xTronic HD2515U Manuel D'utilisation Et D'entretien page 35

Masquer les pouces Voir aussi pour xTronic HD2515U:

Publicité

General Range Troubleshooting Tips:
1. Verify that gas shut-off valve is in the ON position and the gas supply to the house is not shut off.
2. Verify that the burner caps are positioned and the burner ports are not clogged. Clear ports with a stiff nylon
bristle toothbrush if clogged.
3. Verify that the ignitors are clean and dry.
4. Verify that there is no draft in the room.
5. Check the power supply. It should be properly grounded with the correct polarity. Verify that the unit is plugged in
and the circuit breaker is not tripped.
Note: When the electrical power connection has been activated at the first power up or after an outage, the ignitors
may spark once or twice even though all burner knobs are in the off position.
If the cooktop is still not operating properly, please contact your dealer or call BSH Customer Service at (866)
44SIEMENS.
Replacement Parts
Replacement parts are available through your Siemens dealer. Contact Siemens Service for a dealer near you:
866- 44SIEMENS
(447-4363).