Operating instructions SATA air check set
8.2. Proceed with test
Note!
During the test procedure, ensure that the air check set is used in the
correct position [5-1]. The bottom part must point downwards and the
connection nipple must point upwards.
■ Connect the connection nipple [4-2] to the compressed air circuit.
■ Open the compressed air control button [4-3] by slowly turning counter-
clockwise until the pressure gauge shows [4-1] 0.8 bar.
■ After 10 minutes, close the compressed air control button completely by
turning clockwise and end the test procedure.
8.3. Check test membrane
■ Disconnect the connection nipple [4-2] from the compressed air circuit.
■ Unscrew bottom part [3-2] from air check set [3-1].
■ Remove O-ring [2-1], test membrane [1-3] and sintered filter [1-1].
■ Check test membrane [6-3] with magnifying glass [6-2] and light [6-1]
for any possible soiling.
Possible signs of soiling
Soiling on test membrane
Discolouring
Particles
Scratches
8.4. Clean air check set
Attention!
Physical damage from incorrect cleaning
Immersion in solvents or cleaning agent can damage the O-ring.
→ Do not place immerse the O-ring in solvent or cleaning agent.
■ Clean bottom part [7-1] and air check set with clean cleaning agent
(not reclaimed agent) using a brush [7-2].
■ Blow clean compressed air through to dry the bottom part and air check
set [7-3].

9. Care and storage

Careful handling together with constant care of the product is necessary
to ensure that the air check set functions properly.
Öle und / oder Kondensat in Druckluft
Oxyde oder Gummi in Druckluft
Trockene Partikel in Druckluft die nicht
an der Prüfmembrane kleben
EN
Ursache
31