NOTE: in the event of a two-phase + neutral power supply
(380-415 V 2N~), before connecting to the power supply y-
ou must first remove the indicated cables from the TB1 ter-
minal block and connect them to the TB2 terminal block
(the latter reserved for power supply of the heater).
A: a single-phase line.
B: two single-phase lines.
1
2
TB2
A
1
2
1
2
TB1
TB3
TB2
1
2
1
2
TB1
TB3
B
TB2
1
2
1
2
TB1
TB3
3
B1
J7
J8
B2
J7
J8
In the event that not enough electricity is available, it is still pos-
sible to activate an electronic consumption limiter, operating with-
in the electronic control box (please refer to the wiring diagrams
included in this manual).
This operation can only be performed by authorised Jacuzzi®
technicians.
When installation is complete, the cable clamp and the cover
of the box must be hermetically closed.
1
Start-up Instructions
2
Read each step in its entirety before proceeding with that step.
Remove any dirt from the spa. Although the spa shell has been
polished at the factory, you may want to treat it with a specially
formulated spa cleaner and wax available from your dealer prior
to filling the first time.
Filling the Spa
Remove the filter cover, then remove both filter cartridges as
outlined in section "Cleaning The Filters".
Position the end of the hose inside the filter connection and fill
the spa until the level of water covers all of the nozzles, without
however reaching the headrest.
Do not overfill your spa.
N.B.: If your water is extremely hard, it is preferable to fill halfway with hard
water and the rest of the way with softened water. Or, you may fill entirely
with hard water if you use a special water additive.
Always fill the spa from both filter connections, so as to expel air
trapped in the pumps. Otherwise the air may remain trapped,
preventing the pumps from circulating the water.
After filling, make sure both filters are installed properly before
applying power to the spa. (refer to sec. "Cleaning The Filters").
Checks
Open the cabinet access panel and check all pump fittings to make
sure they are tight. Loosening can occur during shipping and handling.
Turn on Power
Turn on power to spa from the main switch (refer to the chapter
"Electrical safety". The heater and circulation pump will auto-
matically activate.
The flashing of the water temperature icon together with "COOL"
or "ICE" on the display of the control panel may be normal as the
water in the system is often cold; please refer to the "Problem
resolving - Display messages" section.
Start up
Activating the pump(s)
N.B.: do not start the pump(s) if the water does not cover the hi-
ghest pump nozzles.
Addition of chemcial additives at first start-up
Please refer to the Jacuzzi system water treatment guide and relative
catalogue for details on water quality maintenance, the methods and
warnings governing the use of relative chemical products.
32