ELMON relay 32-312
Safety Relay
12. Technical specifi cati ons
Supply voltage
Mains voltage:
Low voltage:
Terminal resistance oft the sensor
nominal value
upper switching point R
lower switching point R
Relay stages
Nominal current DC
Nominal current AC
Mechanical life-ti me
Saft ey Relay
Fuse type
Safety relay switching ti mes
Switching off delay
(response ti me)
Turn-off ti me
Housing
Dimensions (HxWxD)
Housing
Housing incl . cable clamps
Protecti on class
with M16-cable clamps
with M16-blanking plug
Weight
Temperature range
Connecti on terminals
ti ghtening torque
Connecti on cable cross-secti on
single- or fi ne-stranded cable 0,75-1,5 mm
Certi fi cati ons
Electronics
Electromechanics
All voltages connected to the switching unit
must be safely isolated!
*Not included in the scope of delivery
U
230 V AC 50/60 Hz
Netz
P
= 3 VA
max
U
24 V AC/DC ±10 %
E
I
= 85 mA; I
= 180mA (100ms)
E
max
R
= 8,2 kΩ
nom
> 12 kΩ
AO
< 5 kΩ
AU
DC-13 / 24 V / 2 A
AC-15 / 30 V / 2 A
>10
actuati ons
6
M 2 A 5 x 20 glass tube*
< 10 ms
500 ms
Polycarbonate with transparent cover
80 x 120 x 55 mm
102 x 120 x 55 mm
IP65
IP54
460 g
-20°C to +55°C
0,5 Nm
2
EN ISO 13849-1:2015
Category 3 PL e
MTTFd 180 years, DC 90%
MTTFd 3757 years, DC 90 %
B10d 1000000
MTTFd 190 years (Nop 52560)
21