11. Taking out of service and disposal

The products manufactured by ASO are intended solely for commercial use (B2B). At the end of use, the
products are to be disposed of according to all local, regional and nati onal regulati ons. Products can also be
returned to ASO, which will then dispose of them properly.
12. Technical specifi cati ons
Supply voltage
Terminal resistance of the safety contact edges
nominal value
upper switching point
lower switching point
Relay stages
Nominal current DC
Nominal current AC
Mech. life-ti me
Safety relay switching ti mes
Switching off delay (response ti me)
Switching on delay
Assembly
Plug in card for verti cally plugging into a controller with Phoenix
connector MSTBVA 2,5/11-G-5,08
Dimensions: (HxWxD)
Protecti on class
Weight
Temperature range
Connecti on cable cross-secti on
single- or fi ne-stranded cable 0,75-1,5 mm
Certi fi cati ons (In accordance with ELMON inducti ve 71-242)
DIN EN ISO 13849-1:2015 Category 3 PL e
MTTFd 170 years, DC 91%
Elektronik
MTTFd 1616 years, DC 99 %
Elektromechanik
B10d 1000000
MTTFd 190 years (Nop 52560)
Safety device acc. to DIN EN 12978
All voltages connected to the switching unit must
be safely isolated!
20
U
24 V DC ±10%
E
I
= 85 mA; I
= 180mA (100ms)
E
max
Stati onary
contact edge
contact edge
R
= 8,2 kΩ
nom
R
> 12 kΩ
AO
R
< 5 kΩ
AU
3 A
30 V DC
3 A
30 V AC
>10
actuati ons
6
Stati onary
contact edge
< 10 ms
500 ms (Power on 700 ms)
82 x 78 x 27 mm
IP00
115 g
-25°C to +55°C
2
Travelling
= 8,2 kΩ
> 20 kΩ
< 2,5 kΩ
Travelling
contact edge
< 30 ms
EC type-examinati on no.:
44 205 13 031832
Test report no.:
3525 3024