Safety Relay
5. Applicati on examples
+24 V DC
B1
X1
X2
ELMON relay 32-312
B2
13
14
1
K3
2
K1
A1
A2
0 V DC
Circuit diagram in zero-potenti al state. Sensor not actuated.
6. Device overview
6.1 Versions
ELMON relay 32-312
Polycarbonate housing with screw connecti ons for on-wall mounti ng in harsh environments.
6.2 Signal indicators
LED Stat. Opening (red)
actuated (on) - interrupted (fl ashes)
LED Stat. Closing (red)
actuated (on) - interrupted (fl ashes)
LED POWER (green)
Functi onal test (on)
Error message (pulse output)
16
Y1
Y2
23
24
3
K3
4
K2
A1
A2
L1 L2 L3
A1
I1 . 1
I1 . 2
K1
1
3
SPS
2
4
Machine
Control
M M
A2
Q1 . 1
K3
A1
A2
L1 L2 L3
K2
5
1
3
5
6
2
4
6