Télécharger Imprimer la page

SICK HTF18 Mode D'emploi page 21

Publicité

11
Technical specifications
Laser class
Sensing range
Sensing range max.
Light spot diameter/distance
Supply voltage U
B
Output current I
max.
Communication mode
IO-Link
Switching frequency
Max. response time
Enclosure rating
Protection class
Circuit protection
Ambient operating temperature
1)
Object with 90 % remission (based on standard white DIN 5033)
2)
Limit values. U
connections reverse-polarity protected. Residual ripple max 5 V
B
3)
Limit values
4)
With light / dark ratio 1:1, deviating values possible with IO Link
Usage category: AC-15, DC-13 (EN 60947-1)
5)
5)
Signal transit time with resistive load
6)
Replaces IP69 K pursuant to ISO 20653: 2013-03
7)
Rated voltage AC/DC 250 V, overvoltage category II
8)
valid for Q\ on Pin2, if configured with software
8)
A = U
-connections reverse polarity protected
B
B = inputs and output reverse-polarity protected
D = outputs overcurrent and short-circuit protected
9)
Reference voltage DC 50 V
11.1
Dimensional drawing
8017858.1A15 / 2020-12-14 | SICK
Subject to change without notice
AC version,
cable
TECHNICAL SPECIFICATIONS
HTF18
-M / -L /-U
0 ... 150 mm
0 ... 150 mm
0 ... 300 mm
0 ... 300 mm
1)
6 mm / 150 mm
6 mm / 150 mm
DC 10 ... 30 V
AC 90 ... 250 V
2)
≤ 100 mA
≤ 100 mA
COM2
COM2
1.1
1.1
1,000 Hz
1,000 Hz
4)
≤ 0.5 ms
≤ 0.5 ms
5)
IP67, IP69
IP67, IP69
6)
III
II
7)
A, B, D
A, B, D
8)
-40 ... +60 °C
-40 ... +60 °C
PP
16.2
(0.64)
13.1
(0.52)
D
B
A
C
7.9
(0.31)
2
5
1
Snap connection for flush ring (sold sep‐
1
aratly)
Mounting hole
2
HTF18L
1
40 ... 200 mm
40 ... 300 mm
1)
2 mm / 120 mm
DC 10 ... 30 V
3)
≤ 100 mA
COM2
1.1
1,000 Hz
4)
≤ 0.5 ms
5)
IP67, IP69
6)
III
A, B, D
8)
8)
-10 ... +55 °C
34.4
(1.35)
10.5
(0.41)
4
7.5
(0.30)
3
0.9
(0.04)
M18 x 1
11
1)
2)
4)
5)
6)
21

Publicité

loading

Ce manuel est également adapté pour:

Htf18l