7
COMMISSIONING
7
Commissioning
7.1
Alignment
7.2
Check the application conditions
16
-xxxxxI
Q1 = L.ON
2
-xxxxxD
-xxxxxG
Q1 = D.ON
-xxxxxK
1
Adjustabl
-xxxxxN
e OFF
Delay
-xxxxxK
2
Q1 = L.ON
1
L/D Selection Switch in in the "D" Dark Switching position
2
L/D Selection Switch in in the "L" Light Switching position
Align the sensor with a fixed background. You must ensure that the optical opening
(front screen) of the sensor is completely clear [see
Figure 1: Alignment
Sensing range
Check the application conditions: Adjust the sensing range and distance to the object
or background and the remission capability of the object according to the correspond‐
ing diagram [see
figure
X] (x = sensing range, y = transition range between the set
sensing range (background) and object as a % of the sensing range (object remis‐
sion/background remission)). Remission: 6% = black 1, 18% = gray 2, 90% = white 3
(referring to standard white as per DIN 5033).
The minimum distance (= y) for reliable object detection can be determined from the
diagram
[figure
X1] as follows:
Example: x = 150 mm, y = 15 => 15% of 150 mm = 23 mm. That is, the distance
between the object and the background must be at least 123 mm.
figure
1].
8017858.1A15 / 2020-12-14 | SICK
Subject to change without notice