Maximum capacity of contacts
The total power of the outputs listed below must not exceed the maximum output power [Accessories]
Device
Accessories
Additional light
Flashing beacon
Operator status warning light
Command and control devices
1
STOP button (NC contact)
This stops the operator and excludes automatic closing. Use a control device to resume movement.
If the contact is not used it must be short circuited.
2
Control device (NO contact)
Open command
When the [HOLD-TO-RUN] function is active, the control device must be connected during OPENING.
3
Control device (NO contact)
Close command
When the [HOLD-TO-RUN] function is active, the control device must be connected during CLOSING.
Control device (NO contact)
4
Step-by-step command
Sequential command
See DIP switch 2 on the functions menu.
Antenna with RG58 cable
5
Insert the AF card into the corresponding connector for remote control with transmitter.
If the chosen signalling device can be fitted with an antenna, use the terminal shown to connect it.
Output
10-11
E-E3
E-W
10 - 5
1
2
3 3P 4
5
7
2 C1 CX B1 B2
Power supply (V)
24 AC
230 AC
230 AC
24 AC
Power (W)
40
60
25
3