PROGRAMMING
Functions menu
L
N
U
V
W
X
Y
E E3
Automatic closure
Automatic closure
The function does not work if any of the safety devices are triggered when an obstacle is detected, or after a complete stop, or during a power outage.
Set the waiting time before closing, see the Settings section.
DIP switch 1
Command 2-7
The function associates a command to the device connected on 2-7.
DIP switch 2
Open command
Enable the opening command from the transmitter.
DIP switch 3
Pre-flashing
Use this function to activate the flashing beacon 5 seconds before any manoeuvre.
DIP 4
Obstacle with motor stopped
With the function active and the operator stopped, an open or close command is not performed if the safety devices detect an obstacle.
The function is active when the passage is open or closed, or after a complete stop.
DIP switch 5
Hold-to-run
With the function active, the operator stops moving (opening or closing) when the control device is released.
Activation of the function excludes all other control devices.
DIP switch 6
Not used
Leave the DIP switch in the OFF position.
DIP switch 7
CX input
Enable terminal on CX.
Associate a function with input CX, see DIP switch 2 on the 2-position dial.
DIP switch 8
L1T
L2T
CT
0 12 24
2
FA1
FC1 FA2 FC2
TS 10
10 11
S
1
2
3 3P 4
5
7
2 C1 CX B1 B2
ON - Activated
OFF - Deactivated
ON - Sequential command (open-stop-close-stop)
OFF - Step-by-step command (open-close)
ON - Activated
OFF - Deactivated
ON - Activated
OFF - Deactivated
ON - Activated
OFF - Deactivated
ON - Activated
OFF - Deactivated
OFF
ON - Activated
OFF - Deactivated
ON
OFF