Refer to the following chart for correct LP gas orifice spud
ratings and to spud holder card for proper placement.
LP Gas Orifice Spud Chart for Surface Burners
Burner
Rating/Type
Color
15,000 BTU/
Silver
Stacked*
Black/
Orange
14,200
Silver
BTU/ Ultra/
Stacked*
8,000 BTU/
Red/
Semi
Orange
5,000 BTU/
Red/
Auxi
Blue
1,200 BTU/
Black/
Stacked/
Orange
Simmer*
*Not in all kits/models.
NOTE: Refer to the model/serial/rating plate located on the
oven frame behind the top right-hand side of the oven door
for proper sizing of spuds for each burner location.
6. Place Natural gas orifice spuds in the orifice spud bag.
IMPORTANT: Keep the Natural gas orifice spuds in case
of reinstallation with Natural gas.
7. Replace the burner base.
8. Replace burner cap.
9. Repeat steps 1 to 7 for the remaining burners.
Complete Installation (Natural Gas to LP Gas)
1. Refer to the "Make Gas Connection" section for proper
connection of the range to the gas supply.
2. Refer to the "Electronic Ignition System" section for proper
burner ignition and operation.
3. Refer to the "Adjust Flame Height" section for burner flame
adjustments.
IMPORTANT: You may have to adjust the low setting for
each cooktop burner.
Checking for proper cooktop burner flame is very important.
Natural gas flames do not have yellow tips.
4. Refer to "Complete Installation" in the "Installation
Instructions" section of this manual to complete this
procedure.
IMPORTANT: Make sure to save the orifices that have
just been replaced in the conversion.
ID
Size (mm)
Number
Placement
1.05
L105
LF
0.32
L32
1.05
L105
LF/RF
0.85
L85
RR/CTR
0.65
L65
LR
0.32
L32
LF (Simmer)

Natural Gas Conversion

WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Install anti-tip bracket to floor or wall per installation
instructions.
Slide range back so rear range foot is engaged in the
slot of the anti-tip bracket.
Re-engage anti-tip bracket if range is moved.
Do not operate range without anti-tip bracket installed
and engaged.
Failure to follow these instructions can result in death
or serious burns to children and adults.
1. Turn manual shut-off valve to the closed position.
A
A. To range
B. Shut-off valve (closed position)
C. Gas supply line
2. Unplug range or disconnect power.
To Convert Gas Pressure Regulator
(LP Gas to Natural Gas)
1. Move the range out from the wall.
2. Locate the gas pressure regulator at the lower right
corner on the back of the range.
A. Gas pressure regulator
IMPORTANT: Do not remove the gas pressure regulator.
3. Remove the front lower panel of the range.
4. Disconnect the blower motor electrical connections.
5. Disconnect the downdraft blower bellows from the range.
B
C
A