6. Visually check that there is an air gap between the Blower
Motor Cover and the bottom of the range to ensure proper
blower motor ventilation.
7. Rotate blower motor cover so the bellows are in their final
position. Ensure the rear of the bellow flange is engaged
in the retaining bracket.
Retaining
Rotate cover
bracket
8 Secure the front of the blower bellow flange to the range
frame with the supplied #8–18 x
Connect Blower Electrical Parts
1. Locate the capacitor (in Blower Motor Kit).
NOTE: The capacitor is supplied with a small harness
that terminates in a two-pin connector as shown.
Post 1
2. Locate the capacitor storage tray in front of the blower
bellow connection point in the lower right side of the range.
Final position
⁄
" screw.
3
8
Screw
Post 2
Capacitor
storage tray
3. Place capacitor in tray.
4. Secure the capacitor with the capacitor retention bracket;
then, install the bracket screw.
5. Secure the blower motor strain relief, near the quick
connection end, to the blower electrical terminal cover
with the two provided screws.
6. Locate the two-pin connector on the blower motor wire
harness and connect it to the two-pin capacitor connector.
7. Locate the 4-pin connector on the blower motor wire
and plug it into the terminal connection point directly
behind the capacitor storage tray.
NOTE: The terminal release (clip point) will be facing
toward the front of the range.
Retention
bracket
15