2. Without blower or service connections installed, fit
the range in its final installation position.
3. Remove the Front Lower Access Panel of the range
by gently lifting on the panel; then pull outward.
4. Place level on the oven bottom, as indicated in one of
the two figures below, depending on the size of the level.
Check with the level side to side and front to back. If range
is not level, use a wrench or pliers to adjust leveling legs up
or down until the range is level.
NOTE: Range must be level for satisfactory baking
performance and best cleaning results using AquaLift
Self-Clean Technology.
5. Place a strip of masking tape on the floor, in front
of the lower front frame, and mark a line flush with
the front of the frame.
NOTE: Be sure to keep the line even with the front frame.
6. Remove the range from opening. Be sure not to remove
tape during range removal.
7. Offset the line marked in step 5 by 1" (2.5 cm) towards
the rear of the range opening.
12
8. Remove five felt pads from the gasket strip (found
in the blower accessory kit).
9. Remove the paper backing from the felt pads and apply
to the bottom of the three (3) blower motor tabs and two
(2) to the bottom of the Lower Filter Enclosure.
NOTE: Felt pads reduce motor noise and aid in mounting
to uneven floors.
10. Position the blower assembly from "Assemble
Recirculation Housing" so the front edge of the Lower
Filter Enclosure is aligned with the mark made in step 4.
Align the center mark of the Lower Filter Enclosure with
the center line previously marked on the floor.
®
Secure the Blower
1. Drill three Z\," (3 mm) pilot holes using the blower motor
tabs as guides.
2. Mount the blower motor to the floor with the three #10 x 1"
screws provided.
NOTE: If the range height adjustment is significant,
the blower may need to be shimmed to ensure proper
installation.
3. Remove masking tape from floor.
1
2
3
†
AQUALIFT is a registered trademark of Whirlpool, U.S.A.
®